Heating performance & equipment details
Ranges include the 564 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 18–22.5 | 564 / 564 |
| EER2 · BTU/Wh | 10–13 | 564 / 564 |
| HSPF2 · BTU/Wh | 8.1–9.5 | 564 / 564 |
| Cooling capacity · BTU/h | 32,000–36,000 | 564 / 564 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 33,800–39,500 | 371 / 564 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 29,200–34,800 | 564 / 564 |
| Heating capacity at 5°F / −15°C · BTU/h | 25,200–29,600 | 564 / 564 |
| COP at 5°F / −15°C | 1.88–2.1 | 564 / 564 |
| Equipment / loop type | HP - Split System | 564 / 564 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 564 / 564 |
| Compressor staging | Continuously variable | 564 / 564 |
| Connected capability | No | 564 / 564 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CSAH*4812AM*+UI+ furnace: 986TD42060C17***Cold climate designationAHRI reference: 215933695 | 19.00 | 9.00 | 26000 | 1.96 | EPA 3726944 → |
CSAH*4212AM*+UI+ furnace: 935CB60080C21***Cold climate designationAHRI reference: 215933375 | 19.00 | 9.00 | 26600 | 1.92 | EPA 3726992 → |
CSAH*4212AM*+UI+ furnace: 88*TB48090C17***Cold climate designationAHRI reference: 215933335 | 19.00 | 9.00 | 26600 | 1.92 | EPA 3727110 → |
CAA**4221AM*+UI+ furnace: 987MC42060C17***Cold climate designationAHRI reference: 215932285 | 19.00 | 9.50 | 26400 | 2.04 | EPA 3727219 → |
CAA**4221AM*+UI+ furnace: 987MC60060C21***Cold climate designationAHRI reference: 215932295 | 19.00 | 9.50 | 27200 | 2.00 | EPA 3727233 → |
CSAH*4212AM*+UI+ furnace: 986TD66120C24***Cold climate designationAHRI reference: 215933495 | 19.00 | 9.00 | 26600 | 1.94 | EPA 3727572 → |
CSAH*3612AM*+UI+ furnace: 83*CA36040C17***Cold climate designationAHRI reference: 215933025 | 19.00 | 9.00 | 27000 | 1.90 | EPA 3727844 → |
CSAH*3612AM*+UI+ furnace: 83*CA48060C17***Cold climate designationAHRI reference: 215933035 | 19.00 | 9.00 | 26800 | 1.92 | EPA 3727854 → |
CSAH*4212AM*+UI+ furnace: 986TD66100C21***Cold climate designationAHRI reference: 215933485 | 19.00 | 9.00 | 26600 | 1.94 | EPA 3727958 → |
CSAH*4212AM*+UI+ furnace: 987MC60080C21***Cold climate designationAHRI reference: 215933425 | 19.00 | 9.00 | 26600 | 1.94 | EPA 3728141 → |
CSAH*4212AM*+UI+ furnace: 987MC66100C21***Cold climate designationAHRI reference: 215933435 | 19.00 | 9.00 | 26600 | 1.94 | EPA 3728150 → |
CSAH*4212AM*+UI+ furnace: 987MC66120C24***Cold climate designationAHRI reference: 215933445 | 19.00 | 9.00 | 26600 | 1.94 | EPA 3728160 → |
CSAH*4812AM*+UI+ furnace: 88*TB48070C17***Cold climate designationAHRI reference: 215933555 | 19.00 | 9.00 | 26800 | 1.94 | EPA 3730007 → |
CSAH*4812AM*+UI+ furnace: 935CB48060C17***Cold climate designationAHRI reference: 215933605 | 19.00 | 9.00 | 27000 | 1.94 | EPA 3730080 → |
CSAH*6012AM*+UI+ furnace: 987MC42060C17***Cold climate designationAHRI reference: 215933855 | 19.00 | 9.00 | 25800 | 1.96 | EPA 3730172 → |
CSAH*6012AM*+UI+ furnace: 987MC60060C21***Cold climate designationAHRI reference: 215933865 | 19.00 | 9.00 | 26400 | 1.94 | EPA 3730182 → |
CSAH*6012AM*+UI+ furnace: 987MC42080C17***Cold climate designationAHRI reference: 215933875 | 19.00 | 9.00 | 26400 | 1.94 | EPA 3730192 → |
CSAH*3612AM*+UI+ furnace: 88*TB60090C21***Cold climate designationAHRI reference: 215933105 | 19.00 | 9.00 | 26600 | 1.94 | EPA 3730236 → |
CSAH*3612AM*+UI+ furnace: 88*TB60070C21***Cold climate designationAHRI reference: 215933085 | 19.00 | 9.00 | 26800 | 1.94 | EPA 3730327 → |
CSAH*3612AM*+UI+ furnace: 88*TB48090C17***Cold climate designationAHRI reference: 215933095 | 19.00 | 9.00 | 26800 | 1.94 | EPA 3730339 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →