293VAN036**AA*
Evolution 23 VS Heat Pump · source records, page 23
564 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for 293VAN036**AA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 564 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 18–22.5 | 564 / 564 |
| EER2 · BTU/Wh | 10–13 | 564 / 564 |
| HSPF2 · BTU/Wh | 8.1–9.5 | 564 / 564 |
| Cooling capacity · BTU/h | 32,000–36,000 | 564 / 564 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 33,800–39,500 | 371 / 564 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 29,200–34,800 | 564 / 564 |
| Heating capacity at 5°F / −15°C · BTU/h | 25,200–29,600 | 564 / 564 |
| COP at 5°F / −15°C | 1.88–2.1 | 564 / 564 |
| Equipment / loop type | HP - Split System | 564 / 564 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 564 / 564 |
| Compressor staging | Continuously variable | 564 / 564 |
| Connected capability | No | 564 / 564 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CAA**4321AM*+UI+ furnace: 986TD42060C17***Cold climate designationAHRI reference: 215932375 | 19.50 | 9.50 | 26000 | 2.06 | EPA 3727744 → |
CSAH*4812AM*+UI+ furnace: 83*CA36040C17***Cold climate designationAHRI reference: 215933505 | 19.50 | 9.00 | 26600 | 1.92 | EPA 3727978 → |
CSAH*6012AM*+UI+ furnace: 88*TB60090C21***Cold climate designationAHRI reference: 215933795 | 19.50 | 9.00 | 25800 | 1.98 | EPA 3728271 → |
CSAH*6012AM*+UI+ furnace: 88*TB60110C21***Cold climate designationAHRI reference: 215933805 | 19.50 | 9.00 | 26000 | 1.96 | EPA 3728281 → |
CSAH*6012AM*+UI+ furnace: 987TA66100C21***Cold climate designationAHRI reference: 215940235 | 19.50 | 9.00 | 26000 | 1.96 | EPA 3728339 → |
CSAH*6012AM*+UI+ furnace: 987TA66120C24***Cold climate designationAHRI reference: 215940245 | 19.50 | 9.00 | 26000 | 1.96 | EPA 3728349 → |
CAA**4821AM*+UI+ furnace: 88*TB36045C17***Cold climate designationAHRI reference: 215932405 | 19.50 | 9.00 | 27200 | 1.94 | EPA 3729443 → |
CAA**4221AM*+UI+ furnace: 987TA60080C21***Cold climate designationAHRI reference: 215939695 | 19.50 | 9.00 | 26800 | 1.94 | EPA 3729565 → |
CAA**4821AM*+UI+ furnace: 986TD42060C17***Cold climate designationAHRI reference: 215932505 | 19.50 | 9.00 | 26000 | 1.96 | EPA 3729834 → |
CSAH*4812AM*+UI+ furnace: 935CB66100C21***Cold climate designationAHRI reference: 215933625 | 19.50 | 9.00 | 26400 | 1.96 | EPA 3730004 → |
CSAH*4812AM*+UI+ furnace: 88*TB60070C21***Cold climate designationAHRI reference: 215933565 | 19.50 | 9.00 | 26600 | 1.96 | EPA 3730017 → |
CSAH*4812AM*+UI+ furnace: 88*TB48090C17***Cold climate designationAHRI reference: 215933575 | 19.50 | 9.00 | 26600 | 1.96 | EPA 3730027 → |
CSAH*4812AM*+UI+ furnace: 88*TB60090C21***Cold climate designationAHRI reference: 215933585 | 19.50 | 9.00 | 26400 | 1.96 | EPA 3730060 → |
CSAH*4812AM*+UI+ furnace: 88*TB66135C24***Cold climate designationAHRI reference: 215933595 | 19.50 | 9.00 | 26400 | 1.96 | EPA 3730069 → |
CSAH*6012AM*+UI+ furnace: 987MC60080C21***Cold climate designationAHRI reference: 215933885 | 19.50 | 9.00 | 26000 | 1.96 | EPA 3730202 → |
CSAH*6012AM*+UI+ furnace: 987MC66100C21***Cold climate designationAHRI reference: 215933895 | 19.50 | 9.00 | 26000 | 1.96 | EPA 3730212 → |
CSAH*6012AM*+UI+ furnace: 986TD42080C17***Cold climate designationAHRI reference: 215933925 | 19.50 | 9.00 | 26400 | 1.96 | EPA 3730355 → |
CSAH*6012AM*+UI+ furnace: 986TD66100C21***Cold climate designationAHRI reference: 215933935 | 19.50 | 9.00 | 26000 | 1.96 | EPA 3730365 → |
CAA**3617AM*+UI+ furnace: 88*TB48090C17***Cold climate designationAHRI reference: 215932075 | 19.50 | 9.00 | 27000 | 1.92 | EPA 3732289 → |
CAA**3617AM*+UI+ furnace: 83*CB36040C17***Cold climate designationAHRI reference: 215939605 | 19.50 | 9.00 | 26800 | 1.92 | EPA 3732411 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.