293VAN036**AA*
Evolution 23 VS Heat Pump · source records, page 20
564 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for 293VAN036**AA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 564 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 18–22.5 | 564 / 564 |
| EER2 · BTU/Wh | 10–13 | 564 / 564 |
| HSPF2 · BTU/Wh | 8.1–9.5 | 564 / 564 |
| Cooling capacity · BTU/h | 32,000–36,000 | 564 / 564 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 33,800–39,500 | 371 / 564 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 29,200–34,800 | 564 / 564 |
| Heating capacity at 5°F / −15°C · BTU/h | 25,200–29,600 | 564 / 564 |
| COP at 5°F / −15°C | 1.88–2.1 | 564 / 564 |
| Equipment / loop type | HP - Split System | 564 / 564 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 564 / 564 |
| Compressor staging | Continuously variable | 564 / 564 |
| Connected capability | No | 564 / 564 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CAA**6024AM*+UI+ furnace: 83*CA60100C21***Cold climate designationAHRI reference: 215932525 | 20.00 | 9.00 | 26000 | 1.94 | EPA 3729854 → |
CVAVA3621XMA*+UI+ furnace: 88*TB36045C17***Cold climate designationAHRI reference: 215935615 | 20.00 | 8.10 | 29000 | 2.00 | EPA 3729971 → |
CAA**4821AM*+UI+ furnace: 987TA60080C21***Cold climate designationAHRI reference: 215939765 | 20.00 | 9.50 | 26400 | 2.06 | EPA 3731452 → |
CAA**4821AM*+UI+ furnace: 987TA66100C21***Cold climate designationAHRI reference: 215939775 | 20.00 | 9.50 | 26200 | 2.06 | EPA 3731461 → |
CAA**6024AM*+UI+ furnace: 935CB60080C21***Cold climate designationAHRI reference: 215932575 | 20.00 | 9.00 | 26000 | 1.94 | EPA 3731711 → |
CAA**6024AM*+UI+ furnace: 987MC60060C21***Cold climate designationAHRI reference: 215932595 | 20.00 | 9.00 | 26400 | 1.96 | EPA 3731731 → |
CAA**6024AM*+UI+ furnace: 987MC60080C21***Cold climate designationAHRI reference: 215932605 | 20.00 | 9.00 | 26000 | 1.96 | EPA 3731741 → |
CAA**6121AM*+UI+ furnace: 986TD60080C21***Cold climate designationAHRI reference: 215939825 | 20.00 | 9.00 | 26200 | 1.96 | EPA 3731773 → |
CVAVA3621XMA*+UI+ furnace: 987MC42060C17***Cold climate designationAHRI reference: 215935705 | 20.00 | 8.10 | 27000 | 2.00 | EPA 3731977 → |
CAA**6024AM*+UI+ furnace: 986TD60080C21***Cold climate designationAHRI reference: 215939785 | 20.00 | 9.00 | 26000 | 1.96 | EPA 3732100 → |
CAA**6024AM*+UI+ furnace: 987TA60080C21***Cold climate designationAHRI reference: 215939795 | 20.00 | 9.00 | 26000 | 1.96 | EPA 3732110 → |
CAA**6121AM*+UI+ furnace: 935CB48060C17***Cold climate designationAHRI reference: 215932745 | 20.00 | 9.00 | 26600 | 1.96 | EPA 3733438 → |
CAA**6121AM*+UI+ furnace: 935CB60080C21***Cold climate designationAHRI reference: 215932755 | 20.00 | 9.00 | 26200 | 1.96 | EPA 3733448 → |
CAA**4821AM*+UI+ furnace: 987MC60080C21***Cold climate designationAHRI reference: 215932495 | 20.00 | 9.50 | 26400 | 2.06 | EPA 3734175 → |
CVAVA3617XMA*+UI+ furnace: 987MC42060C17***Cold climate designationAHRI reference: 215935565 | 20.00 | 8.10 | 27200 | 2.00 | EPA 3734223 → |
CVAVA3617XMA*+UI+ furnace: 986TD42060C17***Cold climate designationAHRI reference: 215935575 | 20.00 | 8.10 | 27200 | 2.00 | EPA 3734231 → |
CVAVA3621XMA*+UI+ furnace: 987TA48060C17***Cold climate designationAHRI reference: 217106183 | 20.00 | 8.10 | 28800 | 2.00 | EPA 4509851 → |
CVAVA4221XMA*+UI+ furnace: 987TA48060C17***Cold climate designationAHRI reference: 217106187 | 20.00 | 8.10 | 28800 | 2.00 | EPA 4529745 → |
CAA**6121AM*+UI+ furnace: 987TA48080C17***Cold climate designationAHRI reference: 217106168 | 20.00 | 9.00 | 26600 | 1.96 | EPA 4529761 → |
CAA**3617AM*+UI+ furnace: 83*CA36040C17***Cold climate designationAHRI reference: 215932035 | 19.50 | 9.50 | 27200 | 1.98 | EPA 3724431 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →