293VAN036**AA*
Evolution 23 VS Heat Pump · source records, page 18
564 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for 293VAN036**AA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 564 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 18–22.5 | 564 / 564 |
| EER2 · BTU/Wh | 10–13 | 564 / 564 |
| HSPF2 · BTU/Wh | 8.1–9.5 | 564 / 564 |
| Cooling capacity · BTU/h | 32,000–36,000 | 564 / 564 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 33,800–39,500 | 371 / 564 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 29,200–34,800 | 564 / 564 |
| Heating capacity at 5°F / −15°C · BTU/h | 25,200–29,600 | 564 / 564 |
| COP at 5°F / −15°C | 1.88–2.1 | 564 / 564 |
| Equipment / loop type | HP - Split System | 564 / 564 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 564 / 564 |
| Compressor staging | Continuously variable | 564 / 564 |
| Connected capability | No | 564 / 564 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CVAMA4821XMA*+UI+ furnace: 987MC42060C17***Cold climate designationAHRI reference: 215934955 | 20.50 | 8.50 | 27600 | 2.08 | EPA 3734114 → |
CAA**4821AM*+UI+ furnace: 88*TB60110C21***Cold climate designationAHRI reference: 215932445 | 20.50 | 9.50 | 26200 | 2.06 | EPA 3734124 → |
CVAVA3621XMA*+UI+ furnace: 986TD60080C21***Cold climate designationAHRI reference: 215940505 | 20.50 | 8.50 | 28200 | 2.06 | EPA 3734420 → |
CVAVA4221XMA*+UI+ furnace: 986TD60080C21***Cold climate designationAHRI reference: 215940615 | 20.50 | 8.50 | 28200 | 2.06 | EPA 3735441 → |
CVAVA4221XMA*+UI+ furnace: 987TA60080C21***Cold climate designationAHRI reference: 215940665 | 20.50 | 8.50 | 28200 | 2.06 | EPA 3735668 → |
CVAVA3621XMA*+UI+ furnace: 987TA60080C21***Cold climate designationAHRI reference: 215940555 | 20.50 | 8.50 | 28200 | 2.06 | EPA 3735773 → |
CVAVA3817XMA*+UI+ furnace: 987TA48060C17***Cold climate designationAHRI reference: 217106185 | 20.50 | 8.50 | 29400 | 2.02 | EPA 4509852 → |
CVAVA3621XMA*+UI+ furnace: 987TA48080C17***Cold climate designationAHRI reference: 217106184 | 20.50 | 8.50 | 28600 | 2.06 | EPA 4529743 → |
CVAVA4221XMA*+UI+ furnace: 987TA48080C17***Cold climate designationAHRI reference: 217106188 | 20.50 | 8.50 | 28600 | 2.06 | EPA 4529746 → |
CAA**6121AM*+UI+ furnace: 83*CA60100C21***Cold climate designationAHRI reference: 215932675 | 20.00 | 9.00 | 26200 | 1.94 | EPA 3724455 → |
CAA**6121AM*+UI+ furnace: 88*TB48070C17***Cold climate designationAHRI reference: 215932695 | 20.00 | 9.00 | 26400 | 1.94 | EPA 3724475 → |
CVAMA3617XMA*+UI+ furnace: 987MC42060C17***Cold climate designationAHRI reference: 215934715 | 20.00 | 8.10 | 27200 | 2.00 | EPA 3724885 → |
CVAMA3617XMA*+UI+ furnace: 986TD42060C17***Cold climate designationAHRI reference: 215934725 | 20.00 | 8.10 | 27200 | 2.00 | EPA 3724898 → |
CVAMA4221XMA*+UI+ furnace: 987MC42060C17***Cold climate designationAHRI reference: 215934735 | 20.00 | 8.10 | 27000 | 2.00 | EPA 3724911 → |
CAA**6121AM*+UI+ furnace: 987TA60080C21***Cold climate designationAHRI reference: 215939875 | 20.00 | 9.00 | 26200 | 1.96 | EPA 3725023 → |
CAA**4221AM*+UI+ furnace: 83*CB36040C17***Cold climate designationAHRI reference: 215939655 | 20.00 | 9.50 | 26600 | 2.06 | EPA 3725099 → |
CAA**4221AM*+UI+ furnace: 83*CB48060C17***Cold climate designationAHRI reference: 215939665 | 20.00 | 9.50 | 26600 | 2.04 | EPA 3725109 → |
CAA**4221AM*+UI+ furnace: 83*CA36040C17***Cold climate designationAHRI reference: 215932185 | 20.00 | 9.50 | 26800 | 2.00 | EPA 3725644 → |
CAA**4221AM*+UI+ furnace: 83*CA48060C17***Cold climate designationAHRI reference: 215932195 | 20.00 | 9.50 | 26800 | 2.00 | EPA 3725654 → |
CAA**6121AM*+UI+ furnace: 986TD42060C17***Cold climate designationAHRI reference: 215932815 | 20.00 | 9.00 | 25600 | 1.98 | EPA 3725725 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.