BRYANT HEATING AND COOLING SYSTEMS / AIR-SOURCE HEAT PUMP

293VAN036**AA*

Evolution 23 VS Heat Pump · source records, page 13

564 published source records · source checked Sep 21, 2026

SEER2 range18–22.5BTU/Wh
HSPF2 range8.1–9.5BTU/Wh
Cooling capacity32,000–36,000BTU/h

Each efficiency range summarizes published EPA records for 293VAN036**AA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 564 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh18–22.5564 / 564
EER2 · BTU/Wh10–13564 / 564
HSPF2 · BTU/Wh8.1–9.5564 / 564
Cooling capacity · BTU/h32,000–36,000564 / 564
Heating capacity at 47°F / 8.3°C · BTU/h33,800–39,500371 / 564
Heating capacity at 17°F / −8.3°C · BTU/h29,200–34,800564 / 564
Heating capacity at 5°F / −15°C · BTU/h25,200–29,600564 / 564
COP at 5°F / −15°C1.88–2.1564 / 564
Equipment / loop typeHP - Split System564 / 564
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)564 / 564
Compressor stagingContinuously variable564 / 564
Connected capabilityNo564 / 564

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CVAVA3621XMA*+UI+ furnace: 987MC66100C21***Cold climate designationAHRI reference: 21593574521.008.50280002.08EPA 3732017 →
CVAVA6121XMA*+UI+ furnace: 88*TB36045C17***Cold climate designationAHRI reference: 21593686521.008.50290002.02EPA 3733542 →
CVAMA6021XMA*+UI+ furnace: 88*TB36045C17***Cold climate designationAHRI reference: 21593517521.008.50294002.04EPA 3733588 →
CVAVA3817XMA*+UI+ furnace: 88*TB36045C17***Cold climate designationAHRI reference: 21593582521.008.50296002.00EPA 3733720 →
CVAVA4224XMA*+UI+ furnace: 987MC60060C21***Cold climate designationAHRI reference: 21593621521.008.50288002.02EPA 3733809 →
CVAVA6021XMA*+UI+ furnace: 88*TB36045C17***Cold climate designationAHRI reference: 21593658521.008.50294002.04EPA 3733960 →
CVAVA4221XMA*+UI+ furnace: 83*CB36040C17***Cold climate designationAHRI reference: 21594062521.008.50278002.04EPA 3735451 →
CVAVA4221XMA*+UI+ furnace: 83*CB48060C17***Cold climate designationAHRI reference: 21594063521.008.50280002.06EPA 3735461 →
CVAVA3621XMA*+UI+ furnace: 83*CB36040C17***Cold climate designationAHRI reference: 21594051521.008.50278002.06EPA 3735500 →
CVAVA3621XMA*+UI+ furnace: 83*CB48060C17***Cold climate designationAHRI reference: 21594052521.008.50280002.06EPA 3735510 →
CVAVA4221XMA*+UI+ furnace: 987TA66100C21***Cold climate designationAHRI reference: 21594067521.008.50280002.08EPA 3735678 →
CVAVA3621XMA*+UI+ furnace: 987TA66100C21***Cold climate designationAHRI reference: 21594056521.008.50280002.08EPA 3735783 →
CVAVA4824XMA*+UI+ furnace: 986TD60080C21***Cold climate designationAHRI reference: 21594072521.008.50284002.06EPA 3736016 →
CVAVA4824XMA*+UI+ furnace: 987TA60080C21***Cold climate designationAHRI reference: 21594073521.008.50284002.06EPA 3736026 →
CVAMA4421XMA*+UI+ furnace: 986TD42060C17***Cold climate designationAHRI reference: 21594237121.008.50280002.06EPA 3736085 →
CVAMA4921XMA*+UI+ furnace: 987MC42060C17***Cold climate designationAHRI reference: 21594238121.008.50280002.08EPA 3736094 →
CVAMA4921XMA*+UI+ furnace: 986TD42060C17***Cold climate designationAHRI reference: 21594239121.008.50280002.06EPA 3736106 →
CVAMA6021XMA*+UI+ furnace: 987MC42060C17***Cold climate designationAHRI reference: 21594240121.008.50280002.08EPA 3736115 →
CVAMA6021XMA*+UI+ furnace: 986TD42060C17***Cold climate designationAHRI reference: 21594241121.008.50280002.06EPA 3736125 →
CVAMA4421XMA*+UI+ furnace: 987MC42060C17***Cold climate designationAHRI reference: 21594236121.008.50280002.06EPA 3737464 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →