BRYANT HEATING AND COOLING SYSTEMS / AIR-SOURCE HEAT PUMP

293VAN036**AA*

Evolution 23 VS Heat Pump · source records, page 11

564 published source records · source checked Sep 21, 2026

SEER2 range18–22.5BTU/Wh
HSPF2 range8.1–9.5BTU/Wh
Cooling capacity32,000–36,000BTU/h

Each efficiency range summarizes published EPA records for 293VAN036**AA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 564 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh18–22.5564 / 564
EER2 · BTU/Wh10–13564 / 564
HSPF2 · BTU/Wh8.1–9.5564 / 564
Cooling capacity · BTU/h32,000–36,000564 / 564
Heating capacity at 47°F / 8.3°C · BTU/h33,800–39,500371 / 564
Heating capacity at 17°F / −8.3°C · BTU/h29,200–34,800564 / 564
Heating capacity at 5°F / −15°C · BTU/h25,200–29,600564 / 564
COP at 5°F / −15°C1.88–2.1564 / 564
Equipment / loop typeHP - Split System564 / 564
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)564 / 564
Compressor stagingContinuously variable564 / 564
Connected capabilityNo564 / 564

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CVAVA4924XMA*+UI+ furnace: 986TD60080C21***Cold climate designationAHRI reference: 21594076521.508.50286002.06EPA 3736056
CVAVA4924XMA*+UI+ furnace: 987TA60080C21***Cold climate designationAHRI reference: 21594077521.508.50286002.06EPA 3736139
CVAVA6021XMA*+UI+ furnace: 986TD60080C21***Cold climate designationAHRI reference: 21594080521.508.50286002.02EPA 3736169
CVAVA6021XMA*+UI+ furnace: 987TA60080C21***Cold climate designationAHRI reference: 21594085521.508.50286002.02EPA 3736229
CVAVA6024XMA*+UI+ furnace: 986TD60080C21***Cold climate designationAHRI reference: 21594087521.508.50286002.04EPA 3736252
CVAVA6024XMA*+UI+ furnace: 987TA60080C21***Cold climate designationAHRI reference: 21594088521.508.50286002.04EPA 3736376
CVAVA6121XMA*+UI+ furnace: 987TA48080C17***Cold climate designationAHRI reference: 21710619121.508.50288002.06EPA 4529748
CVAMA4921XMA*+UI+ furnace: 987MC60060C21***Cold climate designationAHRI reference: 21593508521.008.50290002.02EPA 3724513
CVAVA3621XMA*+UI+ furnace: 986TD66100C21***Cold climate designationAHRI reference: 21593577521.008.50280002.06EPA 3724790
CVAVA6024XMA*+UI+ furnace: 987MC60060C21***Cold climate designationAHRI reference: 21593680521.008.50288002.02EPA 3724821
CVAMA4421XMA*+UI+ furnace: 88*TB36045C17***Cold climate designationAHRI reference: 21593480521.008.50294002.04EPA 3725291
CVAVA4824XMA*+UI+ furnace: 935CB60080C21***Cold climate designationAHRI reference: 21593634521.008.50284002.06EPA 3725375
CVAVA3817XMA*+UI+ furnace: 935CB48060C17***Cold climate designationAHRI reference: 21593586521.008.50292002.02EPA 3725812
CVAVA3817XMA*+UI+ furnace: 987MC42060C17***Cold climate designationAHRI reference: 21593587521.008.50280002.06EPA 3725838
CVAVA3817XMA*+UI+ furnace: 987MC42080C17***Cold climate designationAHRI reference: 21593588521.008.50292002.00EPA 3725921
CVAVA3817XMA*+UI+ furnace: 986TD42060C17***Cold climate designationAHRI reference: 21593589521.008.50280002.00EPA 3725929
CVAMA6021XMA*+UI+ furnace: 987MC60060C21***Cold climate designationAHRI reference: 21593526521.008.50290002.02EPA 3725972
CVAVA4221XMA*+UI+ furnace: 83*CA36040C17***Cold climate designationAHRI reference: 21593594521.008.50284002.04EPA 3726026
CVAVA4221XMA*+UI+ furnace: 83*CA48060C17***Cold climate designationAHRI reference: 21593595521.008.50282002.04EPA 3726038
CVAVA4824XMA*+UI+ furnace: 987MC60060C21***Cold climate designationAHRI reference: 21593636521.008.50288002.02EPA 3726172

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →