293VAN036**AA*
Evolution 23 VS Heat Pump
564 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for 293VAN036**AA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 564 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 18–22.5 | 564 / 564 |
| EER2 · BTU/Wh | 10–13 | 564 / 564 |
| HSPF2 · BTU/Wh | 8.1–9.5 | 564 / 564 |
| Cooling capacity · BTU/h | 32,000–36,000 | 564 / 564 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 33,800–39,500 | 371 / 564 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 29,200–34,800 | 564 / 564 |
| Heating capacity at 5°F / −15°C · BTU/h | 25,200–29,600 | 564 / 564 |
| COP at 5°F / −15°C | 1.88–2.1 | 564 / 564 |
| Equipment / loop type | HP - Split System | 564 / 564 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 564 / 564 |
| Compressor staging | Continuously variable | 564 / 564 |
| Connected capability | No | 564 / 564 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CVAVA6124XMA*+UI+ furnace: 88*TB60090C21***Cold climate designationAHRI reference: 215936925 | 22.50 | 8.50 | 28200 | 2.06 | EPA 3726375 → |
CVAVA6124XMA*+UI+ furnace: 88*TB60110C21***Cold climate designationAHRI reference: 215936935 | 22.50 | 8.50 | 28200 | 2.06 | EPA 3726386 → |
CVAVA6124XMA*+UI+ furnace: 935CB66100C21***Cold climate designationAHRI reference: 215936945 | 22.50 | 8.50 | 28200 | 2.06 | EPA 3726395 → |
CVAMA6124XMA*+UI+ furnace: 88*TB60090C21***Cold climate designationAHRI reference: 215935455 | 22.50 | 8.50 | 28200 | 2.06 | EPA 3727802 → |
CVAMA6124XMA*+UI+ furnace: 88*TB60110C21***Cold climate designationAHRI reference: 215935465 | 22.50 | 8.50 | 28200 | 2.06 | EPA 3727810 → |
CVAMA6124XMA*+UI+ furnace: 88*TB66135C24***Cold climate designationAHRI reference: 215935475 | 22.50 | 8.50 | 28200 | 2.04 | EPA 3727987 → |
CVAMA6124XMA*+UI+ furnace: 935CB66100C21***Cold climate designationAHRI reference: 215935485 | 22.50 | 8.50 | 28200 | 2.06 | EPA 3727997 → |
CVAMA4921XMA*+UI+ furnace: 935CB66100C21***Cold climate designationAHRI reference: 215935075 | 22.00 | 8.50 | 28400 | 2.04 | EPA 3724503 → |
CVAMA4921XMA*+UI+ furnace: 987MC66100C21***Cold climate designationAHRI reference: 215935115 | 22.00 | 8.50 | 28600 | 2.02 | EPA 3724543 → |
FE5BNBD60L*+UICold climate designationAHRI reference: 215933965 | 22.00 | 9.50 | 25200 | 2.08 | EPA 3724669 → |
CVAVA6024XMA*+UI+ furnace: 88*TB60090C21***Cold climate designationAHRI reference: 215936755 | 22.00 | 8.50 | 28400 | 2.04 | EPA 3724699 → |
CVAVA6024XMA*+UI+ furnace: 88*TB60110C21***Cold climate designationAHRI reference: 215936765 | 22.00 | 8.50 | 28400 | 2.04 | EPA 3724709 → |
CVAVA6024XMA*+UI+ furnace: 88*TB66135C24***Cold climate designationAHRI reference: 215936775 | 22.00 | 8.50 | 28400 | 2.04 | EPA 3724719 → |
CVAVA6024XMA*+UI+ furnace: 935CB66100C21***Cold climate designationAHRI reference: 215936795 | 22.00 | 8.50 | 28400 | 2.06 | EPA 3724810 → |
CVAVA6121XMA*+UI+ furnace: 88*TB48070C17***Cold climate designationAHRI reference: 215936875 | 22.00 | 9.00 | 28600 | 2.10 | EPA 3725175 → |
CVAVA6121XMA*+UI+ furnace: 935CB66100C21***Cold climate designationAHRI reference: 215936885 | 22.00 | 8.50 | 28400 | 2.04 | EPA 3725185 → |
CVAMA4421XMA*+UI+ furnace: 88*TB48090C17***Cold climate designationAHRI reference: 215934835 | 22.00 | 8.50 | 28600 | 2.02 | EPA 3725321 → |
CVAMA4421XMA*+UI+ furnace: 88*TB60090C21***Cold climate designationAHRI reference: 215934845 | 22.00 | 8.50 | 28400 | 2.04 | EPA 3725331 → |
CVAMA6021XMA*+UI+ furnace: 88*TB48090C17***Cold climate designationAHRI reference: 215935205 | 22.00 | 8.50 | 28600 | 2.04 | EPA 3725695 → |
CVAMA6021XMA*+UI+ furnace: 88*TB60090C21***Cold climate designationAHRI reference: 215935215 | 22.00 | 8.50 | 28400 | 2.04 | EPA 3725705 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →