293VAN024**AA*
Evolution 23 VS Heat Pump · source records, page 20
430 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for 293VAN024**AA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 430 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 18–23 | 430 / 430 |
| EER2 · BTU/Wh | 10.5–14 | 430 / 430 |
| HSPF2 · BTU/Wh | 8.5–10.5 | 430 / 430 |
| Cooling capacity · BTU/h | 21,600–23,800 | 430 / 430 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 24,800–28,200 | 430 / 430 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 24,000–26,400 | 430 / 430 |
| Heating capacity at 5°F / −15°C · BTU/h | 19,100–23,000 | 430 / 430 |
| COP at 5°F / −15°C | 1.84–2.1 | 430 / 430 |
| Equipment / loop type | HP - Split System | 430 / 430 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 430 / 430 |
| Compressor staging | Continuously variable | 430 / 430 |
| Connected capability | No | 430 / 430 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CSAH*4212AM*+UI+ furnace: 935CB48060C17***Cold climate designationAHRI reference: 217624582 | 19.50 | 9.50 | 19400 | 1.98 | EPA 4499267 → |
CSAH*4212AM*+UI+ furnace: 987MC42060C17***Cold climate designationAHRI reference: 217624584 | 19.50 | 9.50 | 19500 | 1.98 | EPA 4499269 → |
CSAH*4212AM*+UI+ furnace: 987MC42080C17***Cold climate designationAHRI reference: 217624586 | 19.50 | 9.50 | 19400 | 1.98 | EPA 4499271 → |
CSAH*4212AM*+UI+ furnace: 986TD42060C17***Cold climate designationAHRI reference: 217624590 | 19.50 | 9.50 | 19500 | 1.98 | EPA 4499275 → |
CSAH*4212AM*+UI+ furnace: 987TA48080C17***Cold climate designationAHRI reference: 217624596 | 19.50 | 9.50 | 19400 | 1.98 | EPA 4499282 → |
CAA**2417AM*+UI+ furnace: 987TA48060C17***Cold climate designationAHRI reference: 217624306 | 19.50 | 9.50 | 20000 | 1.96 | EPA 4499313 → |
CAA**2517AM*+UI+ furnace: 986TD30040C14***Cold climate designationAHRI reference: 217624324 | 19.50 | 9.50 | 19800 | 1.94 | EPA 4499333 → |
CAA**3617AM*+UI+ furnace: 986TD30040C14***Cold climate designationAHRI reference: 217624382 | 19.50 | 9.50 | 20200 | 1.94 | EPA 4499454 → |
CAA**3717AM*+UI+ furnace: 986TD30040C14***Cold climate designationAHRI reference: 217624408 | 19.50 | 9.50 | 19800 | 1.96 | EPA 4499535 → |
CSAH*2412AM*+UI+ furnace: 83*CB36040C17***Cold climate designationAHRI reference: 217624486 | 19.50 | 9.50 | 19800 | 1.96 | EPA 4499614 → |
CSAH*2412AM*+UI+ furnace: 83*CB48060C17***Cold climate designationAHRI reference: 217624488 | 19.50 | 9.50 | 19800 | 1.98 | EPA 4499617 → |
CSAH*2412AM*+UI+ furnace: 88*TB36070C14***Cold climate designationAHRI reference: 217624492 | 19.50 | 9.50 | 19800 | 1.96 | EPA 4499620 → |
CSAH*2412AM*+UI+ furnace: 88*TB48090C17***Cold climate designationAHRI reference: 217624496 | 19.50 | 9.50 | 19800 | 1.96 | EPA 4499624 → |
CVAMA2417XMA*+UI+ furnace: 986TD30040C14***Cold climate designationAHRI reference: 217624930 | 19.50 | 8.50 | 22600 | 1.90 | EPA 4499976 → |
CVAVA2414XMA*+UI+ furnace: 986TD30040C14***Cold climate designationAHRI reference: 217624942 | 19.50 | 8.50 | 22600 | 1.92 | EPA 4499988 → |
CVAVA2417XMA*+UI+ furnace: 986TD30040C14***Cold climate designationAHRI reference: 217624944 | 19.50 | 8.50 | 22600 | 1.90 | EPA 4499991 → |
CVAVA2514XMA*+UI+ furnace: 986TD30040C14***Cold climate designationAHRI reference: 217624946 | 19.50 | 9.00 | 22800 | 2.02 | EPA 4499993 → |
CAA**2517AM*+UI+ furnace: 987TA30040C14***Cold climate designationAHRI reference: 217992482 | 19.50 | 10.00 | 19800 | 1.94 | EPA 4566754 → |
CAA**3617AM*+UI+ furnace: 987TA30040C14***Cold climate designationAHRI reference: 217992485 | 19.50 | 10.00 | 20200 | 1.90 | EPA 4566758 → |
CAA**3717AM*+UI+ furnace: 987TA30040C14***Cold climate designationAHRI reference: 217992486 | 19.50 | 10.00 | 19800 | 1.96 | EPA 4566760 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →