293VAN024**AA*
Evolution 23 VS Heat Pump · source records, page 18
430 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for 293VAN024**AA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 430 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 18–23 | 430 / 430 |
| EER2 · BTU/Wh | 10.5–14 | 430 / 430 |
| HSPF2 · BTU/Wh | 8.5–10.5 | 430 / 430 |
| Cooling capacity · BTU/h | 21,600–23,800 | 430 / 430 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 24,800–28,200 | 430 / 430 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 24,000–26,400 | 430 / 430 |
| Heating capacity at 5°F / −15°C · BTU/h | 19,100–23,000 | 430 / 430 |
| COP at 5°F / −15°C | 1.84–2.1 | 430 / 430 |
| Equipment / loop type | HP - Split System | 430 / 430 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 430 / 430 |
| Compressor staging | Continuously variable | 430 / 430 |
| Connected capability | No | 430 / 430 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CAA**2417AM*+UI+ furnace: 987MC42060C17***Cold climate designationAHRI reference: 217624296 | 20.00 | 9.50 | 20000 | 1.96 | EPA 4499301 → |
CAA**2417AM*+UI+ furnace: 987MC42080C17***Cold climate designationAHRI reference: 217624298 | 20.00 | 9.50 | 19800 | 1.96 | EPA 4499304 → |
CAA**2417AM*+UI+ furnace: 986TD42060C17***Cold climate designationAHRI reference: 217624302 | 20.00 | 9.50 | 20000 | 1.96 | EPA 4499309 → |
CAA**2417AM*+UI+ furnace: 987TA48080C17***Cold climate designationAHRI reference: 217624308 | 20.00 | 9.50 | 20000 | 1.96 | EPA 4499315 → |
CAA**2517AM*+UI+ furnace: 987TA48060C17***Cold climate designationAHRI reference: 217624330 | 20.00 | 10.00 | 19500 | 2.08 | EPA 4499343 → |
CAA**3017AM*+UI+ furnace: 88*TB36045C17***Cold climate designationAHRI reference: 217624342 | 20.00 | 9.50 | 19800 | 1.98 | EPA 4499413 → |
CAA**3017AM*+UI+ furnace: 987MC42060C17***Cold climate designationAHRI reference: 217624352 | 20.00 | 9.50 | 19800 | 1.96 | EPA 4499423 → |
CAA**3017AM*+UI+ furnace: 987TA48060C17***Cold climate designationAHRI reference: 217624362 | 20.00 | 9.50 | 19800 | 1.98 | EPA 4499434 → |
CAA**3617AM*+UI+ furnace: 88*TB36045C17***Cold climate designationAHRI reference: 217624370 | 20.00 | 9.50 | 19800 | 1.96 | EPA 4499442 → |
CAA**3617AM*+UI+ furnace: 987TA48060C17***Cold climate designationAHRI reference: 217624388 | 20.00 | 9.50 | 19800 | 1.96 | EPA 4499460 → |
CVAMA2417XMA*+UI+ furnace: 987TA48060C17***Cold climate designationAHRI reference: 217625036 | 20.00 | 9.00 | 22200 | 2.02 | EPA 4499492 → |
CVAVA2417XMA*+UI+ furnace: 987TA48060C17***Cold climate designationAHRI reference: 217625054 | 20.00 | 9.00 | 22200 | 2.02 | EPA 4499509 → |
CAA**3717AM*+UI+ furnace: 88*TB36045C17***Cold climate designationAHRI reference: 217624396 | 20.00 | 9.50 | 19600 | 1.96 | EPA 4499524 → |
CAA**3717AM*+UI+ furnace: 987TA48060C17***Cold climate designationAHRI reference: 217624414 | 20.00 | 9.50 | 19600 | 1.96 | EPA 4499542 → |
CAA**3721AM*+UI+ furnace: 987TA48060C17***Cold climate designationAHRI reference: 217624438 | 20.00 | 10.00 | 19400 | 2.08 | EPA 4499567 → |
CAA**4221AM*+UI+ furnace: 987TA48060C17***Cold climate designationAHRI reference: 217624462 | 20.00 | 9.50 | 19700 | 1.96 | EPA 4499590 → |
CVAMA2517XMA*+UI+ furnace: 986TD30040C14***Cold climate designationAHRI reference: 217624932 | 20.00 | 9.00 | 22800 | 1.98 | EPA 4499979 → |
CVAMA3617XMA*+UI+ furnace: 986TD30040C14***Cold climate designationAHRI reference: 217624940 | 20.00 | 9.00 | 22800 | 1.98 | EPA 4499987 → |
CVAVA2517XMA*+UI+ furnace: 986TD30040C14***Cold climate designationAHRI reference: 217624948 | 20.00 | 9.00 | 22800 | 1.98 | EPA 4499995 → |
CSAH*3012AM*+UI+ furnace: 88*TB36070C14***Cold climate designationAHRI reference: 217624520 | 19.50 | 9.50 | 19700 | 1.96 | EPA 4499181 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →