BRYANT HEATING AND COOLING SYSTEMS / AIR-SOURCE HEAT PUMP

291VAN054**AA*

Evolution 21 VS Cold Climate Heat Pump · source records, page 7

155 published source records · source checked Sep 21, 2026

SEER2 range17–21BTU/Wh
HSPF2 range8–10.5BTU/Wh
Cooling capacity47,500–53,500BTU/h

Each efficiency range summarizes published EPA records for 291VAN054**AA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 155 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh17–21155 / 155
EER2 · BTU/Wh10–13155 / 155
HSPF2 · BTU/Wh8–10.5155 / 155
Cooling capacity · BTU/h47,500–53,500155 / 155
Heating capacity at 47°F / 8.3°C · BTU/h51,000–54,500155 / 155
Heating capacity at 17°F / −8.3°C · BTU/h47,500–52,000155 / 155
Heating capacity at 5°F / −15°C · BTU/h45,500–54,000155 / 155
COP at 5°F / −15°C1.78–2155 / 155
Equipment / loop typeHP - Split System155 / 155
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)155 / 155
Compressor stagingContinuously variable155 / 155
Connected capabilityNo155 / 155

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CVAMA4921XMA*+UI+ furnace: 935CB60080C21***AHRI reference: 21558821619.008.00455001.84EPA 4705587
CSAH*6012AM*+UI+ furnace: 88*TB66135C24***Cold climate designationAHRI reference: 21558816818.509.50530001.90EPA 3719686
CAA**4821AM*+UI+ furnace: 987MC60080C21***Cold climate designationAHRI reference: 21558808418.509.50520001.96EPA 3719691
CSAH*6012AM*+UI+ furnace: 987MC66100C21***Cold climate designationAHRI reference: 21558818218.509.50535001.90EPA 3719697
CSAH*6012AM*+UI+ furnace: 987MC60080C21***Cold climate designationAHRI reference: 21558818018.509.50525001.94EPA 3719700
CSAH*6012AM*+UI+ furnace: 987MC66120C24***Cold climate designationAHRI reference: 21558818418.509.50535001.90EPA 3719702
CVAVA6121XMA*+UI+ furnace: 987MC60060C21***AHRI reference: 21558838418.508.00465001.82EPA 3719716
CVAVA6124XMA*+UI+ furnace: 987MC60060C21***AHRI reference: 21558840618.508.00465001.82EPA 3719717
CSAH*6012AM*+UI+ furnace: 935CB66100C21***Cold climate designationAHRI reference: 21558817418.509.50530001.90EPA 3719729
CSAH*6012AM*+UI+ furnace: 987TA60080C21***Cold climate designationAHRI reference: 21558846018.509.50535001.90EPA 3719759
CSAH*6012AM*+UI+ furnace: 83*CA60100C21***Cold climate designationAHRI reference: 21558815418.5010.50535001.90EPA 3719762
CSAH*6012AM*+UI+ furnace: 986TD66120C24***Cold climate designationAHRI reference: 21558819018.509.50530001.90EPA 3719764
CAA**6124AM*+UI+ furnace: 987MC60060C21***Cold climate designationAHRI reference: 21558813018.509.50535001.92EPA 3719784
CSAH*6012AM*+UI+ furnace: 83*CB60100C21***Cold climate designationAHRI reference: 21558845618.509.50530001.90EPA 3719838
CSAH*6012AM*+UI+ furnace: 987TA66120C24***Cold climate designationAHRI reference: 21558846418.509.50530001.90EPA 3719839
CAA**6121AM*+UI+ furnace: 987MC60060C21***Cold climate designationAHRI reference: 21558812018.509.50535001.92EPA 3719848
CSAH*6012AM*+UI+ furnace: 986TD60080C21***Cold climate designationAHRI reference: 21558844818.509.50535001.90EPA 3719851
CSAH*6012AM*+UI+ furnace: 83*CA60080C21***Cold climate designationAHRI reference: 21558815218.5010.00530001.84EPA 3719864
CSAH*6012AM*+UI+ furnace: 987TA66100C21***Cold climate designationAHRI reference: 21558846218.509.50535001.90EPA 3719869
CVAMA6124XMA*+UI+ furnace: 987MC60060C21***AHRI reference: 21558828018.508.00465001.82EPA 3719879

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →