| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 16.5–19 | 158 / 158 |
| EER2 · BTU/Wh | 8–9.8 | 158 / 158 |
| HSPF2 · BTU/Wh | 8.1–9 | 158 / 158 |
| Cooling capacity · BTU/h | 54,000–58,000 | 158 / 158 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 59,000–63,500 | 54 / 158 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 50,500–57,500 | 158 / 158 |
| Heating capacity at 5°F / −15°C · BTU/h | 41,000–46,000 | 158 / 158 |
| COP at 5°F / −15°C | 1.86–2.1 | 158 / 158 |
| Equipment / loop type | HP - Split System | 158 / 158 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 158 / 158 |
| Compressor staging | Continuously variable | 158 / 158 |
| Connected capability | No | 158 / 158 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CVAMA6124XMA*+UI+ furnace: 987MC66100C21***Cold climate designationAHRI reference: 215677274 | 18.50 | 9.00 | 44500 | 2.08 | EPA 3971513 → |
CVAMA6021XMA*+UI+ furnace: 987MC66100C21***Cold climate designationAHRI reference: 215677064 | 18.50 | 9.00 | 45000 | 2.08 | EPA 3971545 → |
CVAMA6021XMA*+UI+ furnace: 986TD66100C21***Cold climate designationAHRI reference: 215677074 | 18.50 | 9.00 | 45000 | 2.08 | EPA 3971552 → |
CVAMA6024XMA*+UI+ furnace: 83*CA60080C21***Cold climate designationAHRI reference: 215677084 | 18.50 | 9.00 | 44000 | 2.08 | EPA 3971568 → |
CVAMA6024XMA*+UI+ furnace: 88*TB60090C21***Cold climate designationAHRI reference: 215677114 | 18.50 | 9.00 | 44000 | 2.08 | EPA 3971593 → |
CVAMA6024XMA*+UI+ furnace: 88*TB60110C21***Cold climate designationAHRI reference: 215677124 | 18.50 | 9.00 | 44000 | 2.08 | EPA 3971607 → |
CVAMA6024XMA*+UI+ furnace: 88*TB66135C24***Cold climate designationAHRI reference: 215677134 | 18.50 | 9.00 | 44000 | 2.08 | EPA 3971620 → |
CVAMA6124XMA*+UI+ furnace: 987MC66120C24***Cold climate designationAHRI reference: 215677284 | 18.50 | 9.00 | 44500 | 2.08 | EPA 3971686 → |
CVAMA6124XMA*+UI+ furnace: 986TD66100C21***Cold climate designationAHRI reference: 215677294 | 18.50 | 9.00 | 44500 | 2.08 | EPA 3971702 → |
CVAVA6021XMA*+UI+ furnace: 88*TB60090C21***Cold climate designationAHRI reference: 215677354 | 18.50 | 9.00 | 44500 | 2.08 | EPA 3971733 → |
CVAVA6021XMA*+UI+ furnace: 88*TB60110C21***Cold climate designationAHRI reference: 215677364 | 18.50 | 9.00 | 44500 | 2.08 | EPA 3971787 → |
CVAVA6021XMA*+UI+ furnace: 987MC66100C21***Cold climate designationAHRI reference: 215677404 | 18.50 | 9.00 | 44500 | 2.08 | EPA 3971861 → |
CVAVA6024XMA*+UI+ furnace: 986TD66120C24***Cold climate designationAHRI reference: 215677554 | 18.50 | 9.00 | 44500 | 2.08 | EPA 3972006 → |
CVAVA6121XMA*+UI+ furnace: 83*CA60080C21***Cold climate designationAHRI reference: 215677564 | 18.50 | 9.00 | 44500 | 2.10 | EPA 3972017 → |
CVAVA6121XMA*+UI+ furnace: 935CB66100C21***Cold climate designationAHRI reference: 215677604 | 18.50 | 9.00 | 44500 | 2.10 | EPA 3972056 → |
CVAVA6021XMA*+UI+ furnace: 986TD66100C21***Cold climate designationAHRI reference: 215677414 | 18.50 | 9.00 | 44500 | 2.08 | EPA 3972072 → |
CVAVA6024XMA*+UI+ furnace: 83*CA60080C21***Cold climate designationAHRI reference: 215677424 | 18.50 | 9.00 | 44000 | 2.08 | EPA 3972081 → |
CVAVA6024XMA*+UI+ furnace: 88*TB60090C21***Cold climate designationAHRI reference: 215677454 | 18.50 | 9.00 | 44000 | 2.08 | EPA 3972106 → |
CVAVA6024XMA*+UI+ furnace: 88*TB60110C21***Cold climate designationAHRI reference: 215677464 | 18.50 | 9.00 | 44000 | 2.08 | EPA 3972113 → |
CVAVA6024XMA*+UI+ furnace: 88*TB66135C24***Cold climate designationAHRI reference: 215677474 | 18.50 | 9.00 | 44000 | 2.08 | EPA 3972126 → |