Heating performance & equipment details
Ranges include the 376 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.5–19.5 | 376 / 376 |
| EER2 · BTU/Wh | 9–10.5 | 376 / 376 |
| HSPF2 · BTU/Wh | 8.5–9.5 | 376 / 376 |
| Cooling capacity · BTU/h | 43,500–49,000 | 376 / 376 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 47,000–50,000 | 376 / 376 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 41,000–47,500 | 376 / 376 |
| Heating capacity at 5°F / −15°C · BTU/h | 33,000–37,600 | 376 / 376 |
| COP at 5°F / −15°C | 1.92–2.2 | 376 / 376 |
| Equipment / loop type | HP - Split System | 376 / 376 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 376 / 376 |
| Compressor staging | Continuously variable | 376 / 376 |
| Connected capability | No | 376 / 376 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CAA**6024AM*+UI+ furnace: 987TA66100C21***Cold climate designationAHRI reference: 215681414 | 18.00 | 9.00 | 33600 | 2.06 | EPA 3975876 → |
CAA**6024AM*+UI+ furnace: 987TA66120C24***Cold climate designationAHRI reference: 215681424 | 18.00 | 9.00 | 33600 | 2.06 | EPA 3975885 → |
CAA**6121AM*+UI+ furnace: 986TD60080C21***Cold climate designationAHRI reference: 215681434 | 18.00 | 9.00 | 33800 | 2.08 | EPA 3975894 → |
CAA**6121AM*+UI+ furnace: 83*CB36040C17***Cold climate designationAHRI reference: 215681444 | 18.00 | 9.00 | 33600 | 2.06 | EPA 3975897 → |
CAA**6121AM*+UI+ furnace: 83*CB60080C21***Cold climate designationAHRI reference: 215681464 | 18.00 | 9.00 | 33400 | 2.08 | EPA 3975924 → |
CAA**6121AM*+UI+ furnace: 987TA60080C21***Cold climate designationAHRI reference: 215681494 | 18.00 | 9.00 | 33800 | 2.08 | EPA 3975956 → |
CAA**6121AM*+UI+ furnace: 987TA66100C21***Cold climate designationAHRI reference: 215681504 | 18.00 | 9.00 | 33800 | 2.08 | EPA 3975965 → |
CAA**6124AM*+UI+ furnace: 986TD60080C21***Cold climate designationAHRI reference: 215681514 | 18.00 | 9.00 | 33800 | 2.08 | EPA 3975972 → |
CAA**6124AM*+UI+ furnace: 83*CB60080C21***Cold climate designationAHRI reference: 215681524 | 18.00 | 9.00 | 33400 | 2.08 | EPA 3975985 → |
CAA**6124AM*+UI+ furnace: 83*CB60100C21***Cold climate designationAHRI reference: 215681534 | 18.00 | 9.00 | 33600 | 2.08 | EPA 3975991 → |
CVAVA4824XMA*+UI+ furnace: 83*CB60100C21***Cold climate designationAHRI reference: 215682194 | 18.00 | 9.00 | 36400 | 2.00 | EPA 3976501 → |
CVAVA4821XMA*+UI+ furnace: 83*CB36040C17***Cold climate designationAHRI reference: 215682104 | 18.00 | 9.00 | 36400 | 2.02 | EPA 3976757 → |
CVAVA4821XMA*+UI+ furnace: 83*CB48060C17***Cold climate designationAHRI reference: 215682114 | 18.00 | 9.00 | 36400 | 2.00 | EPA 3976771 → |
CVAVA4821XMA*+UI+ furnace: 83*CB60100C21***Cold climate designationAHRI reference: 215682134 | 18.00 | 9.00 | 36400 | 2.02 | EPA 3976787 → |
CVAMA4821XMA*+UI+ furnace: 987TA48080C17***Cold climate designationAHRI reference: 217105824 | 18.00 | 9.00 | 37000 | 2.00 | EPA 4001238 → |
CVAVA4821XMA*+UI+ furnace: 987TA48080C17***Cold climate designationAHRI reference: 217105827 | 18.00 | 9.00 | 37000 | 1.98 | EPA 4001241 → |
CAA**4821AM*+UI+ furnace: 83*CA48060C17***Cold climate designationAHRI reference: 215673985 | 17.50 | 9.00 | 34200 | 2.04 | EPA 3967852 → |
CAA**4821AM*+UI+ furnace: 935CB60080C21***Cold climate designationAHRI reference: 215674085 | 17.50 | 9.00 | 34200 | 2.06 | EPA 3967945 → |
CAA**4821AM*+UI+ furnace: 83*CA60100C21***Cold climate designationAHRI reference: 215674005 | 17.50 | 9.00 | 34200 | 2.06 | EPA 3967960 → |
CAA**4821AM*+UI+ furnace: 88*TB48070C17***Cold climate designationAHRI reference: 215674025 | 17.50 | 9.00 | 34400 | 2.04 | EPA 3967987 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.