| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.5–19.5 | 376 / 376 |
| EER2 · BTU/Wh | 9–10.5 | 376 / 376 |
| HSPF2 · BTU/Wh | 8.5–9.5 | 376 / 376 |
| Cooling capacity · BTU/h | 43,500–49,000 | 376 / 376 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 47,000–50,000 | 376 / 376 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 41,000–47,500 | 376 / 376 |
| Heating capacity at 5°F / −15°C · BTU/h | 33,000–37,600 | 376 / 376 |
| COP at 5°F / −15°C | 1.92–2.2 | 376 / 376 |
| Equipment / loop type | HP - Split System | 376 / 376 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 376 / 376 |
| Compressor staging | Continuously variable | 376 / 376 |
| Connected capability | No | 376 / 376 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CAA**6124AM*+UI+ furnace: 987TA66100C21***Cold climate designationAHRI reference: 215681554 | 18.50 | 9.00 | 33600 | 2.06 | EPA 3975271 → |
CAA**6124AM*+UI+ furnace: 987TA66120C24***Cold climate designationAHRI reference: 215681564 | 18.50 | 9.00 | 33600 | 2.06 | EPA 3975282 → |
CVAMA4821XMA*+UI+ furnace: 83*CB60080C21***Cold climate designationAHRI reference: 215681774 | 18.50 | 9.00 | 36200 | 2.00 | EPA 3975562 → |
CVAMA4821XMA*+UI+ furnace: 987TA66100C21***Cold climate designationAHRI reference: 215681804 | 18.50 | 9.00 | 36400 | 2.00 | EPA 3975735 → |
CVAMA4921XMA*+UI+ furnace: 83*CB36040C17***Cold climate designationAHRI reference: 215681824 | 18.50 | 9.00 | 36600 | 2.00 | EPA 3975754 → |
CVAMA4921XMA*+UI+ furnace: 83*CB48060C17***Cold climate designationAHRI reference: 215681834 | 18.50 | 9.00 | 36800 | 2.00 | EPA 3975764 → |
CVAMA4921XMA*+UI+ furnace: 83*CB60100C21***Cold climate designationAHRI reference: 215681854 | 18.50 | 9.00 | 36600 | 2.00 | EPA 3975787 → |
CVAVA4821XMA*+UI+ furnace: 987TA60080C21***Cold climate designationAHRI reference: 215682154 | 18.50 | 9.00 | 36600 | 1.98 | EPA 3976314 → |
CVAVA4821XMA*+UI+ furnace: 987TA66100C21***Cold climate designationAHRI reference: 215682164 | 18.50 | 9.00 | 36400 | 2.00 | EPA 3976325 → |
CVAMA6021XMA*+UI+ furnace: 83*CB36040C17***Cold climate designationAHRI reference: 215681904 | 18.50 | 9.00 | 36600 | 2.00 | EPA 3976356 → |
CVAMA6021XMA*+UI+ furnace: 83*CB48060C17***Cold climate designationAHRI reference: 215681914 | 18.50 | 9.00 | 36800 | 2.00 | EPA 3976364 → |
CVAMA6021XMA*+UI+ furnace: 83*CB60100C21***Cold climate designationAHRI reference: 215681934 | 18.50 | 9.00 | 36600 | 2.00 | EPA 3976388 → |
CVAVA4824XMA*+UI+ furnace: 987TA66120C24***Cold climate designationAHRI reference: 215682224 | 18.50 | 9.00 | 36400 | 2.00 | EPA 3976395 → |
CVAMA6024XMA*+UI+ furnace: 83*CB60100C21***Cold climate designationAHRI reference: 215681994 | 18.50 | 9.00 | 36600 | 2.00 | EPA 3976454 → |
CVAVA4824XMA*+UI+ furnace: 986TD60080C21***Cold climate designationAHRI reference: 215682174 | 18.50 | 9.00 | 36400 | 2.00 | EPA 3976476 → |
CVAVA4824XMA*+UI+ furnace: 83*CB60080C21***Cold climate designationAHRI reference: 215682184 | 18.50 | 9.00 | 36000 | 2.02 | EPA 3976488 → |
CVAVA4824XMA*+UI+ furnace: 987TA60080C21***Cold climate designationAHRI reference: 215682204 | 18.50 | 9.00 | 36400 | 2.00 | EPA 3976513 → |
CVAVA4924XMA*+UI+ furnace: 83*CB60100C21***Cold climate designationAHRI reference: 215682254 | 18.50 | 9.00 | 36600 | 2.00 | EPA 3976624 → |
CVAVA6021XMA*+UI+ furnace: 83*CB36040C17***Cold climate designationAHRI reference: 215682304 | 18.50 | 9.00 | 36600 | 2.00 | EPA 3976672 → |
CVAVA4821XMA*+UI+ furnace: 986TD60080C21***Cold climate designationAHRI reference: 215682094 | 18.50 | 9.00 | 36600 | 1.98 | EPA 3976753 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.