290VAN036**AA*
Evolution 20 VS Heat Pump · source records, page 14
300 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for 290VAN036**AA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 300 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 16–19.5 | 300 / 300 |
| EER2 · BTU/Wh | 9–11.5 | 300 / 300 |
| HSPF2 · BTU/Wh | 8.5–9.5 | 300 / 300 |
| Cooling capacity · BTU/h | 32,600–35,400 | 300 / 300 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 34,000–36,200 | 300 / 300 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 29,400–31,400 | 300 / 300 |
| Heating capacity at 5°F / −15°C · BTU/h | 24,400–26,000 | 300 / 300 |
| COP at 5°F / −15°C | 1.75–2.04 | 300 / 300 |
| Equipment / loop type | HP - Split System | 300 / 300 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 300 / 300 |
| Compressor staging | Continuously variable | 300 / 300 |
| Connected capability | No | 300 / 300 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CSAH*4212AM*+UI+ furnace: 88*TB48090C17***Cold climate designationAHRI reference: 215684070 | 16.50 | 8.50 | 25400 | 1.76 | EPA 3717076 → |
CSAH*4212AM*+UI+ furnace: 987MC66100C21***Cold climate designationAHRI reference: 215684090 | 16.50 | 8.50 | 25200 | 1.78 | EPA 3717078 → |
CSAH*3612AM*+UI+ furnace: 987MC66120C24***Cold climate designationAHRI reference: 215684046 | 16.50 | 8.50 | 25400 | 1.76 | EPA 3717080 → |
CSAH*4212AM*+UI+ furnace: 83*CA48060C17***Cold climate designationAHRI reference: 215684058 | 16.50 | 8.50 | 25400 | 1.78 | EPA 3717100 → |
CSAH*4212AM*+UI+ furnace: 88*TB60070C21***Cold climate designationAHRI reference: 215684068 | 16.50 | 8.50 | 25400 | 1.76 | EPA 3717101 → |
CSAH*4812AM*+UI+ furnace: 88*TB36045C17***Cold climate designationAHRI reference: 215670157 | 16.50 | 8.50 | 25600 | 1.78 | EPA 3719182 → |
CSAH*3612AM*+UI+ furnace: 935CB48060C17***Cold climate designationAHRI reference: 215684030 | 16.00 | 8.50 | 25600 | 1.76 | EPA 3716601 → |
CSAH*3612AM*+UI+ furnace: 935CB60080C21***Cold climate designationAHRI reference: 215684032 | 16.00 | 8.50 | 25400 | 1.76 | EPA 3716647 → |
CSAH*3612AM*+UI+ furnace: 987MC42080C17***Cold climate designationAHRI reference: 215684040 | 16.00 | 8.50 | 25600 | 1.76 | EPA 3716649 → |
CSAH*4212AM*+UI+ furnace: 987MC42060C17***Cold climate designationAHRI reference: 215684084 | 16.00 | 8.50 | 25600 | 1.76 | EPA 3716664 → |
CSAH*3612AM*+UI+ furnace: 986TD42060C17***Cold climate designationAHRI reference: 215684050 | 16.00 | 8.50 | 25800 | 1.76 | EPA 3716669 → |
CSAH*4212AM*+UI+ furnace: 88*TB36045C17***Cold climate designationAHRI reference: 215684062 | 16.00 | 8.50 | 25600 | 1.76 | EPA 3716676 → |
CSAH*3612AM*+UI+ furnace: 88*TB48090C17***Cold climate designationAHRI reference: 215684022 | 16.00 | 8.50 | 25400 | 1.76 | EPA 3716789 → |
CSAH*4812AM*+UI+ furnace: 986TD60080C21***Cold climate designationAHRI reference: 215679864 | 16.00 | 8.50 | 25200 | 1.88 | EPA 3716790 → |
CSAH*3612AM*+UI+ furnace: 987TA66100C21***Cold climate designationAHRI reference: 215679764 | 16.00 | 8.50 | 25400 | 1.76 | EPA 3716819 → |
CSAH*3612AM*+UI+ furnace: 83*CB36040C17***Cold climate designationAHRI reference: 215679714 | 16.00 | 8.50 | 25400 | 1.78 | EPA 3716855 → |
CSAH*4812AM*+UI+ furnace: 986TD42060C17***Cold climate designationAHRI reference: 215670337 | 16.00 | 8.50 | 25400 | 1.78 | EPA 3716870 → |
CSAH*6012AM*+UI+ furnace: 987MC60060C21***Cold climate designationAHRI reference: 215670507 | 16.00 | 8.50 | 25000 | 1.78 | EPA 3716877 → |
CSAH*4212AM*+UI+ furnace: 987TA60080C21***Cold climate designationAHRI reference: 215679834 | 16.00 | 8.50 | 25200 | 1.76 | EPA 3716881 → |
CSAH*4212AM*+UI+ furnace: 987TA66120C24***Cold climate designationAHRI reference: 215679854 | 16.00 | 8.50 | 25200 | 1.78 | EPA 3716882 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →