SEER2 range16–19.5BTU/Wh
HSPF2 range8.5–9.5BTU/Wh
Cooling capacity32,600–35,400BTU/h

Each efficiency range summarizes published EPA records for 290VAN036**AA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 300 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh16–19.5300 / 300
EER2 · BTU/Wh9–11.5300 / 300
HSPF2 · BTU/Wh8.5–9.5300 / 300
Cooling capacity · BTU/h32,600–35,400300 / 300
Heating capacity at 47°F / 8.3°C · BTU/h34,000–36,200300 / 300
Heating capacity at 17°F / −8.3°C · BTU/h29,400–31,400300 / 300
Heating capacity at 5°F / −15°C · BTU/h24,400–26,000300 / 300
COP at 5°F / −15°C1.75–2.04300 / 300
Equipment / loop typeHP - Split System300 / 300
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)300 / 300
Compressor stagingContinuously variable300 / 300
Connected capabilityNo300 / 300

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CSAH*4812AM*+UI+ furnace: 83*CA48060C17***Cold climate designationAHRI reference: 21567013717.008.50252001.88EPA 3716779 →
CSAH*6012AM*+UI+ furnace: 987MC66100C21***Cold climate designationAHRI reference: 21567053717.008.50248001.92EPA 3716788 →
CSAH*6012AM*+UI+ furnace: 986TD42080C17***Cold climate designationAHRI reference: 21567057717.008.50250001.78EPA 3716802 →
CSAH*6012AM*+UI+ furnace: 83*CA48060C17***Cold climate designationAHRI reference: 21567038717.008.50250001.80EPA 3716817 →
CSAH*6012AM*+UI+ furnace: 987MC66120C24***Cold climate designationAHRI reference: 21567054717.008.50248001.80EPA 3716818 →
CSAH*4812AM*+UI+ furnace: 88*TB66135C24***Cold climate designationAHRI reference: 21567022717.008.50252001.90EPA 3716834 →
CAA**3717AM*+UI+ furnace: 83*CB48060C17***Cold climate designationAHRI reference: 21567924417.009.00254001.86EPA 3716852 →
CSAH*4812AM*+UI+ furnace: 88*TB48090C17***Cold climate designationAHRI reference: 21567019717.008.50252001.88EPA 3716853 →
CSAH*6012AM*+UI+ furnace: 88*TB66135C24***Cold climate designationAHRI reference: 21567046717.008.50248001.92EPA 3716854 →
CSAH*4812AM*+UI+ furnace: 987TA66120C24***Cold climate designationAHRI reference: 21567992417.008.50252001.90EPA 3716867 →
CSAH*6012AM*+UI+ furnace: 88*TB60070C21***Cold climate designationAHRI reference: 21567042717.008.50248001.80EPA 3716871 →
CSAH*4812AM*+UI+ furnace: 83*CB36040C17***Cold climate designationAHRI reference: 21567987417.008.50252001.90EPA 3716872 →
CSAH*6012AM*+UI+ furnace: 88*TB60090C21***Cold climate designationAHRI reference: 21567044717.008.50248001.92EPA 3716875 →
CSAH*6012AM*+UI+ furnace: 987MC60080C21***Cold climate designationAHRI reference: 21567052717.008.50248001.80EPA 3716880 →
CSAH*4812AM*+UI+ furnace: 987MC66100C21***Cold climate designationAHRI reference: 21567030717.008.50252001.90EPA 3716889 →
CSAH*4812AM*+UI+ furnace: 88*TB60090C21***Cold climate designationAHRI reference: 21567020717.008.50252001.90EPA 3716897 →
CAA**3717AM*+UI+ furnace: 88*TB36045C17***Cold climate designationAHRI reference: 21568387217.009.00258001.86EPA 3716921 →
CSAH*6012AM*+UI+ furnace: 88*TB60110C21***Cold climate designationAHRI reference: 21567045717.008.50248001.92EPA 3716966 →
CSAH*6012AM*+UI+ furnace: 935CB66100C21***Cold climate designationAHRI reference: 21567048717.008.50248001.92EPA 3716967 →