BRYANT HEATING AND COOLING SYSTEMS / AIR-SOURCE HEAT PUMP

290VAN024**AA*

Evolution 20 VS Heat Pump · source records, page 3

104 published source records · source checked Sep 21, 2026

SEER2 range15.5–18BTU/Wh
HSPF2 range8.5–9BTU/Wh
Cooling capacity22,400–24,200BTU/h

Each efficiency range summarizes published EPA records for 290VAN024**AA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 104 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.5–18104 / 104
EER2 · BTU/Wh9–10.5104 / 104
HSPF2 · BTU/Wh8.5–9104 / 104
Cooling capacity · BTU/h22,400–24,200104 / 104
Heating capacity at 47°F / 8.3°C · BTU/h23,200–24,600104 / 104
Heating capacity at 17°F / −8.3°C · BTU/h19,600–20,800104 / 104
Heating capacity at 5°F / −15°C · BTU/h16,300–17,300104 / 104
COP at 5°F / −15°C1.82–2.02104 / 104
Equipment / loop typeHP - Split System104 / 104
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)104 / 104
Compressor stagingContinuously variable104 / 104
Connected capabilityNo104 / 104

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CAA**2517AM*+UI+ furnace: 83*CB48060C17***Cold climate designationAHRI reference: 21567823417.009.00163002.02EPA 3800175 →
CAA**2517AM*+UI+ furnace: 88*TB36045C17***Cold climate designationAHRI reference: 21568360017.009.00165002.00EPA 3800198 →
CAA**3617AM*+UI+ furnace: 986TD42080C17***Cold climate designationAHRI reference: 21568366417.009.00166001.98EPA 3800232 →
CAA**3717AM*+UI+ furnace: 83*CA36040C17***Cold climate designationAHRI reference: 21568366617.009.00165002.00EPA 3800242 →
CAA**3617AM*+UI+ furnace: 986TD42060C17***Cold climate designationAHRI reference: 21568366217.009.00167001.96EPA 3801259 →
CAA**3617AM*+UI+ furnace: 83*CA36040C17***Cold climate designationAHRI reference: 21568364417.009.00166001.98EPA 3801269 →
CAA**3617AM*+UI+ furnace: 83*CA48060C17***Cold climate designationAHRI reference: 21568364617.009.00166001.98EPA 3801279 →
CAA**3717AM*+UI+ furnace: 88*TB36045C17***Cold climate designationAHRI reference: 21568367017.009.00166001.98EPA 3801281 →
CAA**3017AM*+UI+ furnace: 83*CB36040C17***Cold climate designationAHRI reference: 21567826417.008.50166001.98EPA 3801307 →
CAA**2517AM*+UI+ furnace: 987MC42060C17***Cold climate designationAHRI reference: 21568360817.009.00165002.00EPA 3801324 →
CAA**3717AM*+UI+ furnace: 986TD42080C17***Cold climate designationAHRI reference: 21568368617.009.00165002.00EPA 3801328 →
CAA**3014AM*+UI+ furnace: 88*TB36070C14***Cold climate designationAHRI reference: 21568361817.008.50167001.86EPA 3801362 →
CAA**3617AM*+UI+ furnace: 987MC42060C17***Cold climate designationAHRI reference: 21568365617.009.00167001.98EPA 3801365 →
CAA**3617AM*+UI+ furnace: 987MC42080C17***Cold climate designationAHRI reference: 21568365817.009.00167001.98EPA 3801376 →
CAA**3717AM*+UI+ furnace: 83*CB36040C17***Cold climate designationAHRI reference: 21567834417.009.00164002.00EPA 3801415 →
CAA**3717AM*+UI+ furnace: 987MC42080C17***Cold climate designationAHRI reference: 21568368017.009.00165002.00EPA 3801449 →
CAA**3017AM*+UI+ furnace: 986TD42060C17***Cold climate designationAHRI reference: 21568364017.008.50167001.86EPA 3801468 →
CAA**3017AM*+UI+ furnace: 986TD42080C17***Cold climate designationAHRI reference: 21568364217.009.00167001.98EPA 3801478 →
CAA**3017AM*+UI+ furnace: 83*CA48060C17***Cold climate designationAHRI reference: 21568362417.009.00167001.98EPA 3801490 →
CAA**3617AM*+UI+ furnace: 88*TB36070C14***Cold climate designationAHRI reference: 21568365017.009.00166001.98EPA 3801537 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →