BRYANT HEATING AND COOLING SYSTEMS / AIR-SOURCE HEAT PUMP

288BNV037*0**B*+TSTAT

EVOLUTION V Heat Pump 2-STAGE

71 published source records · source checked Sep 21, 2026

SEER2 range17–18BTU/Wh
HSPF2 range8.1–8.5BTU/Wh
Cooling capacity31,600–33,000BTU/h

Each efficiency range summarizes published EPA records for 288BNV037*0**B*+TSTAT. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 71 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh17–1871 / 71
EER2 · BTU/Wh11.7–1271 / 71
HSPF2 · BTU/Wh8.1–8.571 / 71
Cooling capacity · BTU/h31,600–33,00071 / 71
Heating capacity at 47°F / 8.3°C · BTU/h46,000–48,00071 / 71
Heating capacity at 17°F / −8.3°C · BTU/h30,200–31,00071 / 71
Heating capacity at 5°F / −15°C · BTU/h24,000–24,40071 / 71
COP at 5°F / −15°C1.94–1.9871 / 71
Equipment / loop typeHP - Split System71 / 71
Refrigerant / source-reported GWPR-410A (GWP:2088)71 / 71
Compressor stagingTwo-stage71 / 71
Connected capabilityNo71 / 71

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CNPV*6024AL*+ furnace: 82*SA60090V24***AHRI reference: 21046499018.008.10242001.96EPA 2416850
CNPV*6024AL*+ furnace: 82*TA66135V24***AHRI reference: 21046502318.008.10240001.94EPA 2417237
CNPV*6024AL*+ furnace: 926TB66100V21***AHRI reference: 21046493518.008.10240001.94EPA 2417648
CAP**6124AL*+ furnace: 926TB66100V21***AHRI reference: 21046175818.008.10242001.98EPA 2633491
CAP**6124AL*+ furnace: 926SA66120V24***AHRI reference: 21046174618.008.10242001.98EPA 2633493
CAP**6124AL*+ furnace: 926SA60100V21***AHRI reference: 21046173518.008.10242001.96EPA 2633495
CAP**6121AL*+ furnace: 82*TA60090V21***AHRI reference: 21046142518.008.10244001.98EPA 2633502
CAP**6121AL*+ furnace: 82*SA60090V21***AHRI reference: 21046141218.008.10244001.98EPA 2633503
CAP**6121AL*+ furnace: 926TB66100V21***AHRI reference: 21046132418.008.10242001.96EPA 2633505
CAP**6121AL*+ furnace: 82*TA48090V17***AHRI reference: 21046142318.008.10242001.96EPA 2633506
CAP**6124AL*+ furnace: 926TB60100V21***AHRI reference: 21046197018.008.10244001.96EPA 2633530
CAP**6124AL*+ furnace: 926TB60080V21***AHRI reference: 21046195918.008.10244001.98EPA 2633531
CAP**6124AL*+ furnace: 926TB66120V24***AHRI reference: 21046184918.008.10242001.96EPA 2633532
CAP**6124AL*+ furnace: 82*TA66135V24***AHRI reference: 21046184618.008.10242001.96EPA 2633535
CAP**6124AL*+ furnace: 82*TA60090V21***AHRI reference: 21046183518.008.10244001.98EPA 2633536
CAP**6124AL*+ furnace: 82*SA60090V21***AHRI reference: 21046180218.008.10244001.98EPA 2633537
CAP**6024AL*+ furnace: 926TB66100V21***AHRI reference: 21046097918.008.10242001.96EPA 2633548
CNPV*6024AL*+ furnace: 82*SA60090V21***AHRI reference: 21046497917.508.10240001.94EPA 2416841
CNPV*4824AL*+ furnace: 82*SA66110V24***AHRI reference: 21046467817.508.10242001.94EPA 2416854
CNPV*4824AL*+ furnace: 926TB66100V21***AHRI reference: 21046461217.508.10242001.96EPA 2417003

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →