BRYANT HEATING AND COOLING SYSTEMS / AIR-SOURCE HEAT PUMP

249VAN060**AA*

Preferred 19 SEER2 VS HP

218 published source records · source checked Sep 21, 2026

SEER2 range15.2–17.5BTU/Wh
HSPF2 range8–9BTU/Wh
Cooling capacity54,000–57,500BTU/h

Each efficiency range summarizes published EPA records for 249VAN060**AA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 218 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–17.5218 / 218
EER2 · BTU/Wh10–12218 / 218
HSPF2 · BTU/Wh8–9218 / 218
Cooling capacity · BTU/h54,000–57,500218 / 218
Heating capacity at 47°F / 8.3°C · BTU/h56,500–62,000218 / 218
Heating capacity at 17°F / −8.3°C · BTU/h48,000–50,500218 / 218
Heating capacity at 5°F / −15°C · BTU/h39,000–42,000218 / 218
COP at 5°F / −15°C1.94–2.16218 / 218
Equipment / loop typeHP - Split System218 / 218
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)218 / 218
Compressor stagingContinuously variable218 / 218
Connected capabilityNo218 / 218

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
FT5BD6021X*Cold climate designationAHRI reference: 21869557017.508.10400002.00EPA 4683257
FT5ANBD60L*Cold climate designationAHRI reference: 21791838217.009.00410002.12EPA 4537059
FG5ANBD60L*Cold climate designationAHRI reference: 21791838317.009.00410002.12EPA 4538449
PF5TNBD60L*Cold climate designationAHRI reference: 21791838417.009.00410002.12EPA 4538450
CAA**6124AM*+ furnace: 83*SB60080M21***AHRI reference: 21793251316.508.50405002.05EPA 4541973
CAA**6124AM*+ furnace: 83*CB60080C21***AHRI reference: 21793243816.508.50405002.05EPA 4547273
CVAMA6021XMA*+ furnace: 82*TB66110V21***AHRI reference: 21791862416.008.00390001.96EPA 4536525
CVAMA6021XMA*+ furnace: 935CB66100C21***AHRI reference: 21791865416.008.00390001.96EPA 4536539
CVAMA6124XMA*+ furnace: 927TA66100V21***AHRI reference: 21791989016.008.00405001.96EPA 4536582
CVAVA6121XMA*+ furnace: 82*TB66110V21***AHRI reference: 21792104816.008.00405001.96EPA 4536666
CVAVA6121XMA*+ furnace: 987MC66100C21***AHRI reference: 21792112316.008.00405001.96EPA 4536674
CVAMA6124XMA*+ furnace: 926TC66100V21***AHRI reference: 21791982916.008.00405001.96EPA 4536699
CVAMA6021XMA*+ furnace: 926TC66100V21***AHRI reference: 21791889516.008.00395001.96EPA 4536983
CVAMA6021XMA*+ furnace: 927TA60100V21***AHRI reference: 21791892516.008.00395001.94EPA 4537012
CVAMA6021XMA*+ furnace: 927TA66100V21***AHRI reference: 21791894016.008.00395001.96EPA 4537027
CVAMA6021XMA*+ furnace: 88*TB60090C21***AHRI reference: 21791856416.008.00395001.94EPA 4537062
CVAMA6021XMA*+ furnace: 88*TB60110C21***AHRI reference: 21791857916.008.00395001.94EPA 4537079
CVAMA6021XMA*+ furnace: 987MC66100C21***AHRI reference: 21791869916.008.00395001.94EPA 4537216
CVAVA6121XMA*+ furnace: 935SB66100M21***AHRI reference: 21792119816.008.00405001.96EPA 4537347
CVAVA6121XMA*+ furnace: 986TD66100C21***AHRI reference: 21792122816.008.00405001.96EPA 4537361

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.