249VAN048**AA*
Preferred 19 SEER2 VS HP · source records, page 15
517 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for 249VAN048**AA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 517 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–19 | 517 / 517 |
| EER2 · BTU/Wh | 10–13.5 | 517 / 517 |
| HSPF2 · BTU/Wh | 8.5–10 | 517 / 517 |
| Cooling capacity · BTU/h | 43,500–49,500 | 517 / 517 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 46,500–55,000 | 517 / 517 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 38,500–47,000 | 517 / 517 |
| Heating capacity at 5°F / −15°C · BTU/h | 36,000–41,500 | 517 / 517 |
| COP at 5°F / −15°C | 1.95–2.32 | 517 / 517 |
| Equipment / loop type | HP - Split System | 517 / 517 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 517 / 517 |
| Compressor staging | Continuously variable | 517 / 517 |
| Connected capability | No | 517 / 517 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CAA**6024AM*+ furnace: 935SB66100M21***Cold climate designationAHRI reference: 217929275 | 16.00 | 9.00 | 37000 | 2.10 | EPA 4545220 → |
CAA**6124AM*+ furnace: 935SB60100M21***Cold climate designationAHRI reference: 217930108 | 16.00 | 9.00 | 37200 | 2.10 | EPA 4545427 → |
CAA**6124AM*+ furnace: 986TD60080C21***Cold climate designationAHRI reference: 217930134 | 16.00 | 9.00 | 37400 | 2.08 | EPA 4545454 → |
CAA**6124AM*+ furnace: 986TD66100C21***Cold climate designationAHRI reference: 217930147 | 16.00 | 9.00 | 37600 | 2.08 | EPA 4545466 → |
CAA**4821AM*+ furnace: 926SB60100V21***Cold climate designationAHRI reference: 217928819 | 16.00 | 9.00 | 36800 | 2.10 | EPA 4545581 → |
CAA**4821AM*+ furnace: 935SB60080M21***Cold climate designationAHRI reference: 217928832 | 16.00 | 9.00 | 36800 | 2.08 | EPA 4545594 → |
CSAH*6012AM*+ furnace: 987MC66100C21***Cold climate designationAHRI reference: 217931059 | 16.00 | 9.00 | 36800 | 2.08 | EPA 4545635 → |
CSAH*6012AM*+ furnace: 987MC66120C24***Cold climate designationAHRI reference: 217931072 | 16.00 | 9.00 | 36800 | 2.10 | EPA 4545655 → |
CAA**6024AM*+ furnace: 926TC66120V24***Cold climate designationAHRI reference: 217929353 | 16.00 | 9.00 | 37200 | 2.08 | EPA 4545790 → |
CSAH*6012AM*+ furnace: 926SB66120V24***Cold climate designationAHRI reference: 217931137 | 16.00 | 9.00 | 36800 | 2.08 | EPA 4545914 → |
CAA**6024AM*+ furnace: 926TC60100V21***Cold climate designationAHRI reference: 217929327 | 16.00 | 9.00 | 37200 | 2.10 | EPA 4545946 → |
CAA**6124AM*+ furnace: 987TA60080C21***Cold climate designationAHRI reference: 217930173 | 16.00 | 9.00 | 37400 | 2.08 | EPA 4546210 → |
CAA**6124AM*+ furnace: 987TA66100C21***Cold climate designationAHRI reference: 217930186 | 16.00 | 9.00 | 37600 | 2.08 | EPA 4546218 → |
CAA**6124AM*+ furnace: 927TA60100V21***Cold climate designationAHRI reference: 217930277 | 16.00 | 9.00 | 37400 | 2.10 | EPA 4546257 → |
CAA**6124AM*+ furnace: 927TA66100V21***Cold climate designationAHRI reference: 217930290 | 16.00 | 9.00 | 37000 | 2.10 | EPA 4546269 → |
CAA**6124AM*+ furnace: 927TA66120V24***Cold climate designationAHRI reference: 217930303 | 16.00 | 9.00 | 37600 | 2.08 | EPA 4546282 → |
CAA**6124AM*+ furnace: OVLAAB060154Cold climate designationAHRI reference: 217930316 | 16.00 | 9.00 | 37200 | 2.10 | EPA 4546296 → |
CSAH*6012AM*+ furnace: 987TA66100C21***Cold climate designationAHRI reference: 217931267 | 16.00 | 9.00 | 36800 | 2.08 | EPA 4546599 → |
CAA**6124AM*+ furnace: 82*SB60090V21***Cold climate designationAHRI reference: 217929899 | 16.00 | 9.00 | 37200 | 2.10 | EPA 4546707 → |
CAA**6124AM*+ furnace: 82*SB66135V24***Cold climate designationAHRI reference: 217929925 | 16.00 | 9.00 | 37200 | 2.10 | EPA 4546734 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.