BRYANT HEATING AND COOLING SYSTEMS / AIR-SOURCE HEAT PUMP

249VAN036**AA*

Preferred 19 SEER2 VS HP · source records, page 2

476 published source records · source checked Sep 21, 2026

SEER2 range15.2–18BTU/Wh
HSPF2 range7.8–9BTU/Wh
Cooling capacity33,400–37,600BTU/h

Each efficiency range summarizes published EPA records for 249VAN036**AA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 476 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18476 / 476
EER2 · BTU/Wh10.5–13.5476 / 476
HSPF2 · BTU/Wh7.8–9476 / 476
Cooling capacity · BTU/h33,400–37,600476 / 476
Heating capacity at 47°F / 8.3°C · BTU/h31,800–37,400476 / 476
Heating capacity at 17°F / −8.3°C · BTU/h25,200–37,600476 / 476
Heating capacity at 5°F / −15°C · BTU/h24,600–26,600476 / 476
COP at 5°F / −15°C1.9–2.18476 / 476
Equipment / loop typeHP - Split System476 / 476
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)476 / 476
Compressor stagingContinuously variable476 / 476
Connected capabilityNo476 / 476

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CVAMA4921XMA*+ furnace: 926TC60100V21***Cold climate designationAHRI reference: 21791105016.009.00264002.14EPA 4530581
CVAMA4921XMA*+ furnace: 927TA60100V21***Cold climate designationAHRI reference: 21791108016.009.00264002.14EPA 4530598
CVAVA3817XMA*+ furnace: 926SB48080V17***Cold climate designationAHRI reference: 21791292516.009.00264002.12EPA 4530599
CVAVA3817XMA*+ furnace: 935SB48060M17***Cold climate designationAHRI reference: 21791294016.008.50264002.00EPA 4530695
CVAVA4221XMA*+ furnace: 83*SB60080M21***Cold climate designationAHRI reference: 21791362116.008.50260002.00EPA 4531032
CVAMA4321XMA*+ furnace: 935SB60080M21***Cold climate designationAHRI reference: 21790994516.008.50248002.05EPA 4531297
CVAMA4321XMA*+ furnace: 935SB60100M21***Cold climate designationAHRI reference: 21790996016.008.50252002.05EPA 4531311
CVAMA4321XMA*+ furnace: 935SB66100M21***Cold climate designationAHRI reference: 21790997516.008.50252002.05EPA 4531328
CVAVA4821XMA*+ furnace: 82*SB66110V21***Cold climate designationAHRI reference: 21791421016.009.00262002.14EPA 4531437
CVAVA4821XMA*+ furnace: 83*SB48060M17***Cold climate designationAHRI reference: 21791422516.008.50262002.00EPA 4531439
CVAVA3621XMA*+ furnace: 83*CB60080C21***Cold climate designationAHRI reference: 21791154916.008.50260002.00EPA 4531442
CVAVA4821XMA*+ furnace: 88*TB60110C21***Cold climate designationAHRI reference: 21791433016.009.00262002.14EPA 4531511
CVAMA4321XMA*+ furnace: 83*CB48060C17***Cold climate designationAHRI reference: 21790943416.008.50248002.05EPA 4531563
CVAMA4321XMA*+ furnace: 83*CB60080C21***Cold climate designationAHRI reference: 21790944916.008.50248002.05EPA 4531577
CVAMA4321XMA*+ furnace: 83*CB60100C21***Cold climate designationAHRI reference: 21790946416.008.50250002.05EPA 4531590
CVAMA4321XMA*+ furnace: 82*SB48070V17***Cold climate designationAHRI reference: 21790947916.008.50250002.05EPA 4531603
CVAVA4821XMA*+ furnace: 83*SB60080M21***Cold climate designationAHRI reference: 21791424016.009.00260002.14EPA 4531665
CVAVA4217XMA*+ furnace: 83*CB36040C17***Cold climate designationAHRI reference: 21791307716.008.50258002.00EPA 4531808
CVAMA4321XMA*+ furnace: 987TA48060C17***Cold climate designationAHRI reference: 21791005016.008.50250002.04EPA 4531952
CVAMA4321XMA*+ furnace: 987TA48080C17***Cold climate designationAHRI reference: 21791006516.008.50250002.05EPA 4532009

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →