249VAN036**AA*
Preferred 19 SEER2 VS HP · source records, page 18
476 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for 249VAN036**AA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 476 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–18 | 476 / 476 |
| EER2 · BTU/Wh | 10.5–13.5 | 476 / 476 |
| HSPF2 · BTU/Wh | 7.8–9 | 476 / 476 |
| Cooling capacity · BTU/h | 33,400–37,600 | 476 / 476 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 31,800–37,400 | 476 / 476 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 25,200–37,600 | 476 / 476 |
| Heating capacity at 5°F / −15°C · BTU/h | 24,600–26,600 | 476 / 476 |
| COP at 5°F / −15°C | 1.9–2.18 | 476 / 476 |
| Equipment / loop type | HP - Split System | 476 / 476 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 476 / 476 |
| Compressor staging | Continuously variable | 476 / 476 |
| Connected capability | No | 476 / 476 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CVAVA4821XMA*+ furnace: 926SB60100V21***Cold climate designationAHRI reference: 217914466 | 15.20 | 8.50 | 26400 | 2.02 | EPA 4533046 → |
CVAMA3617XMA*+ furnace: 935SB48060M17***Cold climate designationAHRI reference: 217909160 | 15.20 | 8.50 | 26000 | 2.00 | EPA 4533175 → |
CVAVA4217XMA*+ furnace: 926SB48060V17***Cold climate designationAHRI reference: 217913304 | 15.20 | 8.50 | 26200 | 2.02 | EPA 4533218 → |
CVAMA3617XMA*+ furnace: 986TD42060C17***Cold climate designationAHRI reference: 217909175 | 15.20 | 8.50 | 26000 | 2.02 | EPA 4533300 → |
CVAVA3621XMA*+ furnace: 88*TB48090C17***Cold climate designationAHRI reference: 217911729 | 15.20 | 8.50 | 26400 | 2.02 | EPA 4533334 → |
CVAVA3621XMA*+ furnace: 88*TB60110C21***Cold climate designationAHRI reference: 217911759 | 15.20 | 8.50 | 26000 | 2.00 | EPA 4533365 → |
CVAVA4221XMA*+ furnace: 926SB60100V21***Cold climate designationAHRI reference: 217913862 | 15.20 | 8.50 | 26200 | 2.00 | EPA 4533383 → |
CVAVA4221XMA*+ furnace: 986TD66100C21***Cold climate designationAHRI reference: 217913907 | 15.20 | 8.50 | 26000 | 2.02 | EPA 4533399 → |
CVAVA4821XMA*+ furnace: 926TC60080V21***Cold climate designationAHRI reference: 217914558 | 15.20 | 8.50 | 26400 | 2.02 | EPA 4533478 → |
CVAMA4321XMA*+ furnace: OVMAAB036098Cold climate designationAHRI reference: 217910308 | 15.20 | 8.50 | 25800 | 2.04 | EPA 4533529 → |
CVAVA3721XMA*+ furnace: 82*SB48070V17***Cold climate designationAHRI reference: 217912259 | 15.20 | 8.50 | 26600 | 2.02 | EPA 4533612 → |
CVAVA4821XMA*+ furnace: 926TC60100V21***Cold climate designationAHRI reference: 217914574 | 15.20 | 8.50 | 26200 | 2.02 | EPA 4533638 → |
CVAMA4821XMA*+ furnace: 926TC60080V21***Cold climate designationAHRI reference: 217910746 | 15.20 | 8.50 | 26400 | 2.02 | EPA 4533685 → |
CVAMA4821XMA*+ furnace: 926TC60100V21***Cold climate designationAHRI reference: 217910762 | 15.20 | 8.50 | 26200 | 2.02 | EPA 4533701 → |
CVAVA3721XMA*+ furnace: 82*TB48070V17***Cold climate designationAHRI reference: 217912364 | 15.20 | 8.50 | 26600 | 2.02 | EPA 4533801 → |
CVAMA4321XMA*+ furnace: OVMAAB042112Cold climate designationAHRI reference: 217910323 | 15.20 | 8.50 | 25600 | 2.02 | EPA 4533854 → |
CVAMA4921XMA*+ furnace: 82*TB48070V17***Cold climate designationAHRI reference: 217910942 | 15.20 | 8.50 | 26600 | 2.00 | EPA 4533907 → |
CVAMA4321XMA*+ furnace: 926SB36040V17***Cold climate designationAHRI reference: 217909840 | 15.20 | 8.50 | 25400 | 2.06 | EPA 4533968 → |
CVAMA4821XMA*+ furnace: 927TA60080V21***Cold climate designationAHRI reference: 217910822 | 15.20 | 8.50 | 26400 | 2.02 | EPA 4534027 → |
CVAVA3817XMA*+ furnace: 82*SB36070V14***Cold climate designationAHRI reference: 217912713 | 15.20 | 8.50 | 26400 | 2.02 | EPA 4534035 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.