BRYANT HEATING AND COOLING SYSTEMS / AIR-SOURCE HEAT PUMP

249VAN036**AA*

Preferred 19 SEER2 VS HP · source records, page 11

476 published source records · source checked Sep 21, 2026

SEER2 range15.2–18BTU/Wh
HSPF2 range7.8–9BTU/Wh
Cooling capacity33,400–37,600BTU/h

Each efficiency range summarizes published EPA records for 249VAN036**AA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 476 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18476 / 476
EER2 · BTU/Wh10.5–13.5476 / 476
HSPF2 · BTU/Wh7.8–9476 / 476
Cooling capacity · BTU/h33,400–37,600476 / 476
Heating capacity at 47°F / 8.3°C · BTU/h31,800–37,400476 / 476
Heating capacity at 17°F / −8.3°C · BTU/h25,200–37,600476 / 476
Heating capacity at 5°F / −15°C · BTU/h24,600–26,600476 / 476
COP at 5°F / −15°C1.9–2.18476 / 476
Equipment / loop typeHP - Split System476 / 476
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)476 / 476
Compressor stagingContinuously variable476 / 476
Connected capabilityNo476 / 476

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CAA**3717AM*+ furnace: 82*TB48070V17***Cold climate designationAHRI reference: 21792269815.509.00256002.08EPA 4538224 →
CAA**3717AM*+ furnace: 82*TB48090V17***Cold climate designationAHRI reference: 21792271315.509.00256002.08EPA 4538238 →
CAA**4321AM*+ furnace: 927TA60100V21***AHRI reference: 21792535715.509.00248002.08EPA 4538256 →
CAA**4321AM*+ furnace: 88*TB60090C21***AHRI reference: 21792480115.509.00248002.06EPA 4538359 →
CAA**4321AM*+ furnace: 88*TB60110C21***AHRI reference: 21792481615.509.00246002.06EPA 4538371 →
CAA**4321AM*+ furnace: 82*TB48070V17***AHRI reference: 21792483115.509.00248002.06EPA 4538388 →
CAA**4321AM*+ furnace: 82*TB48090V17***AHRI reference: 21792484615.509.00248002.08EPA 4538401 →
CAA**4321AM*+ furnace: 82*TB60090V21***AHRI reference: 21792484715.509.00248002.08EPA 4538402 →
CAA**3721AM*+ furnace: 987TA60080C21***AHRI reference: 21792364515.509.00248002.08EPA 4538423 →
CAA**3721AM*+ furnace: 987TA66100C21***AHRI reference: 21792366015.509.00248002.06EPA 4538438 →
CAA**4221AM*+ furnace: 926SB60100V21***Cold climate designationAHRI reference: 21792426115.509.00256002.08EPA 4538739 →
CAA**3721AM*+ furnace: 926TC60080V21***AHRI reference: 21792370515.509.00248002.08EPA 4538897 →
CAA**3721AM*+ furnace: 926TC60100V21***AHRI reference: 21792372015.509.00248002.08EPA 4538910 →
CAA**3717AM*+ furnace: 83*SB48060M17***Cold climate designationAHRI reference: 21792262215.509.00254002.08EPA 4539227 →
CAA**4321AM*+ furnace: 927TA60080V21***AHRI reference: 21792534215.509.00248002.08EPA 4539321 →
CAA**3617AM*+ furnace: 83*SB48060M17***Cold climate designationAHRI reference: 21792221515.508.50250002.00EPA 4539339 →
CAA**4821AM*+ furnace: 82*TB66110V21***AHRI reference: 21792570315.509.00252002.08EPA 4539405 →
CAA**4221AM*+ furnace: 82*SB60090V21***Cold climate designationAHRI reference: 21792393015.509.00256002.08EPA 4539514 →
CAA**4221AM*+ furnace: 82*SB66110V21***Cold climate designationAHRI reference: 21792394515.509.00254002.08EPA 4539529 →
CAA**4321AM*+ furnace: 82*SB48090V17***AHRI reference: 21792463615.509.00248002.08EPA 4539551 →