249VAN024**AA*
Preferred 19 SEER2 VS HP · source records, page 31
1,147 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for 249VAN024**AA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 1,147 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–19.5 | 1,147 / 1,147 |
| EER2 · BTU/Wh | 11.5–14 | 1,147 / 1,147 |
| HSPF2 · BTU/Wh | 8–10 | 1,147 / 1,147 |
| Cooling capacity · BTU/h | 22,200–25,400 | 1,147 / 1,147 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 22,400–25,800 | 1,147 / 1,147 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 19,800–25,200 | 1,147 / 1,147 |
| Heating capacity at 5°F / −15°C · BTU/h | 20,000–22,200 | 1,147 / 1,147 |
| COP at 5°F / −15°C | 1.74–2.02 | 1,147 / 1,147 |
| Equipment / loop type | HP - Split System | 1,147 / 1,147 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 1,147 / 1,147 |
| Compressor staging | Continuously variable | 1,147 / 1,147 |
| Connected capability | No | 1,147 / 1,147 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CVAMA3017XMA*+ furnace: 88*TB36045C17***Cold climate designationAHRI reference: 217936517 | 18.00 | 8.50 | 21600 | 1.90 | EPA 4554434 → |
CVAVA3117XMA*+ furnace: 926TC36040V17***Cold climate designationAHRI reference: 217941243 | 18.00 | 8.50 | 22000 | 1.92 | EPA 4554567 → |
CVAMA2517XMA*+ furnace: OVLAAB036098Cold climate designationAHRI reference: 217936367 | 18.00 | 8.50 | 21800 | 1.90 | EPA 4554595 → |
CVAMA2517XMA*+ furnace: OVMAAB036098Cold climate designationAHRI reference: 217936382 | 18.00 | 8.50 | 21800 | 1.90 | EPA 4554747 → |
CVAVA3621XMA*+ furnace: 926TC36040V17***Cold climate designationAHRI reference: 217942614 | 18.00 | 8.50 | 21400 | 1.88 | EPA 4554916 → |
CVAVA2417XMA*+ furnace: 986TD42060C17***Cold climate designationAHRI reference: 217939241 | 18.00 | 8.50 | 20800 | 1.86 | EPA 4555028 → |
CVAVA2517XMA*+ furnace: OVLAAB036098Cold climate designationAHRI reference: 217940136 | 18.00 | 8.50 | 21800 | 1.90 | EPA 4555252 → |
CVAVA2517XMA*+ furnace: OVMAAB036098Cold climate designationAHRI reference: 217940151 | 18.00 | 8.50 | 21800 | 1.90 | EPA 4555267 → |
CVAMA3117XMA*+ furnace: 926TC36040V17***Cold climate designationAHRI reference: 217937410 | 18.00 | 8.50 | 22000 | 1.92 | EPA 4555321 → |
CVAVA2417XMA*+ furnace: 82*SB36045V14***Cold climate designationAHRI reference: 217938894 | 18.00 | 8.50 | 20800 | 1.86 | EPA 4555440 → |
CVAVA3017XMA*+ furnace: 935SB36040M17***Cold climate designationAHRI reference: 217940651 | 18.00 | 8.50 | 21600 | 1.90 | EPA 4555470 → |
CVAVA2417XMA*+ furnace: 935SB48060M17***Cold climate designationAHRI reference: 217939211 | 18.00 | 8.50 | 20800 | 1.88 | EPA 4555487 → |
CVAVA2417XMA*+ furnace: 82*SB48070V17***Cold climate designationAHRI reference: 217938924 | 18.00 | 8.50 | 21000 | 1.88 | EPA 4555559 → |
CVAMA3017XMA*+ furnace: 926SB36060V14***Cold climate designationAHRI reference: 217936669 | 18.00 | 8.50 | 21600 | 1.88 | EPA 4555737 → |
CVAVA2517XMA*+ furnace: 935SB36040M17***Cold climate designationAHRI reference: 217939923 | 18.00 | 8.50 | 21600 | 1.90 | EPA 4555901 → |
CVAVA3617XMA*+ furnace: OVMAAB036098Cold climate designationAHRI reference: 217941849 | 18.00 | 8.50 | 21800 | 1.90 | EPA 4556084 → |
CVAVA2417XMA*+ furnace: 88*TB36045C17***Cold climate designationAHRI reference: 217938984 | 18.00 | 8.50 | 21000 | 1.88 | EPA 4556540 → |
CVAVA2417XMA*+ furnace: 88*TB48090C17***Cold climate designationAHRI reference: 217939029 | 18.00 | 8.50 | 20800 | 1.88 | EPA 4556585 → |
CAA**3617AM*+ furnace: 82*SB48070V17***Cold climate designationAHRI reference: 217950450 | 18.00 | 9.50 | 21200 | 1.94 | EPA 4556754 → |
CAA**3721AM*+ furnace: 926TC48080V17***Cold climate designationAHRI reference: 217944998 | 18.00 | 10.00 | 21200 | 1.98 | EPA 4556797 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →