249VAN024**AA*
Preferred 19 SEER2 VS HP · source records, page 12
1,147 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for 249VAN024**AA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 1,147 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–19.5 | 1,147 / 1,147 |
| EER2 · BTU/Wh | 11.5–14 | 1,147 / 1,147 |
| HSPF2 · BTU/Wh | 8–10 | 1,147 / 1,147 |
| Cooling capacity · BTU/h | 22,200–25,400 | 1,147 / 1,147 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 22,400–25,800 | 1,147 / 1,147 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 19,800–25,200 | 1,147 / 1,147 |
| Heating capacity at 5°F / −15°C · BTU/h | 20,000–22,200 | 1,147 / 1,147 |
| COP at 5°F / −15°C | 1.74–2.02 | 1,147 / 1,147 |
| Equipment / loop type | HP - Split System | 1,147 / 1,147 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 1,147 / 1,147 |
| Compressor staging | Continuously variable | 1,147 / 1,147 |
| Connected capability | No | 1,147 / 1,147 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CVAVA3117XMA*+ furnace: 987MC42060C17***Cold climate designationAHRI reference: 217941076 | 19.00 | 8.50 | 21800 | 1.92 | EPA 4553254 → |
CVAVA2517XMA*+ furnace: 926TC48080V17***Cold climate designationAHRI reference: 217940091 | 19.00 | 8.50 | 21600 | 1.90 | EPA 4553335 → |
CVAVA3621XMA*+ furnace: 935SB66100M21***Cold climate designationAHRI reference: 217942442 | 19.00 | 8.50 | 21200 | 1.88 | EPA 4553354 → |
CVAVA3621XMA*+ furnace: 986TD60080C21***Cold climate designationAHRI reference: 217942487 | 19.00 | 8.50 | 21200 | 1.90 | EPA 4553361 → |
CVAVA3621XMA*+ furnace: 986TD42060C17***Cold climate designationAHRI reference: 217942457 | 19.00 | 8.50 | 21400 | 1.88 | EPA 4553371 → |
CVAVA3621XMA*+ furnace: 926TC48080V17***Cold climate designationAHRI reference: 217942654 | 19.00 | 8.50 | 21200 | 1.90 | EPA 4553385 → |
CVAVA3621XMA*+ furnace: 986TD66100C21***Cold climate designationAHRI reference: 217942502 | 19.00 | 8.50 | 21200 | 1.88 | EPA 4553400 → |
CVAVA3817XMA*+ furnace: 986TD42060C17***Cold climate designationAHRI reference: 217944290 | 19.00 | 8.50 | 21800 | 1.92 | EPA 4553408 → |
CVAVA3817XMA*+ furnace: 987TA48060C17***Cold climate designationAHRI reference: 217944305 | 19.00 | 8.50 | 21800 | 1.90 | EPA 4553422 → |
CVAVA3817XMA*+ furnace: 987TA48080C17***Cold climate designationAHRI reference: 217944320 | 19.00 | 8.50 | 21800 | 1.92 | EPA 4553438 → |
CVAVA3017XMA*+ furnace: 82*SB48090V17***Cold climate designationAHRI reference: 217940393 | 19.00 | 8.50 | 21400 | 1.90 | EPA 4553469 → |
CVAVA3017XMA*+ furnace: 83*SB36040M17***Cold climate designationAHRI reference: 217940408 | 19.00 | 8.50 | 21400 | 1.90 | EPA 4553484 → |
CVAVA3017XMA*+ furnace: 83*SB48060M17***Cold climate designationAHRI reference: 217940423 | 19.00 | 8.50 | 21400 | 1.90 | EPA 4553499 → |
CVAMA3117XMA*+ furnace: 935SB48060M17***Cold climate designationAHRI reference: 217937304 | 19.00 | 8.50 | 21600 | 1.90 | EPA 4553572 → |
CVAVA3617XMA*+ furnace: 88*TB36070C14***Cold climate designationAHRI reference: 217941469 | 19.00 | 8.50 | 21600 | 1.90 | EPA 4553600 → |
CVAVA3617XMA*+ furnace: 88*TB48070C17***Cold climate designationAHRI reference: 217941484 | 19.00 | 8.50 | 21600 | 1.90 | EPA 4553615 → |
CVAVA3617XMA*+ furnace: 88*TB48090C17***Cold climate designationAHRI reference: 217941499 | 19.00 | 8.50 | 21600 | 1.90 | EPA 4553630 → |
CVAMA2517XMA*+ furnace: 986TD42060C17***Cold climate designationAHRI reference: 217936199 | 19.00 | 8.50 | 21600 | 1.90 | EPA 4553655 → |
CVAMA2517XMA*+ furnace: 986TD42080C17***Cold climate designationAHRI reference: 217936214 | 19.00 | 8.50 | 21400 | 1.90 | EPA 4553670 → |
CVAMA2517XMA*+ furnace: 987MC42080C17***Cold climate designationAHRI reference: 217936064 | 19.00 | 8.50 | 21400 | 1.88 | EPA 4553685 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →