BRYANT HEATING AND COOLING SYSTEMS / AIR-SOURCE HEAT PUMP

248TAN060**AA*

2-STAGE 18 SEER HP · source records, page 5

127 published source records · source checked Sep 21, 2026

SEER2 range15.5–17.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity54,000–58,000BTU/h

Each efficiency range summarizes published EPA records for 248TAN060**AA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 127 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.5–17.5127 / 127
EER2 · BTU/Wh11.7–13127 / 127
HSPF2 · BTU/Wh7.8–8.5127 / 127
Cooling capacity · BTU/h54,000–58,000127 / 127
Heating capacity at 47°F / 8.3°C · BTU/h56,500–61,500127 / 127
Heating capacity at 17°F / −8.3°C · BTU/h36,200–38,500127 / 127
Heating capacity at 5°F / −15°C · BTU/h29,600–31,800127 / 127
COP at 5°F / −15°C2.1–2.34127 / 127
Equipment / loop typeHP - Split System127 / 127
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)127 / 127
Compressor stagingTwo-stage127 / 127
Connected capabilityNo127 / 127

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CAA**6121AM*+ furnace: 935SB60100M21***AHRI reference: 21562987016.008.00302002.30EPA 3951117
CAA**6121AM*+ furnace: 986TD66100C21***AHRI reference: 21562991716.008.00304002.25EPA 3951148
CAA**6024AM*+ furnace: 926SB60080V21***AHRI reference: 21562930716.008.00300002.25EPA 3951173
CAA**6024AM*+ furnace: 926SB60100V21***AHRI reference: 21562932016.008.00298002.25EPA 3951189
CAA**6024AM*+ furnace: 926SB66120V24***AHRI reference: 21562933316.008.00298002.25EPA 3951208
CAA**6024AM*+ furnace: 935SB60080M21***AHRI reference: 21562934616.008.00300002.25EPA 3951229
CAA**6121AM*+ furnace: 926TC60080V21***AHRI reference: 21562993116.008.00304002.25EPA 3951256
CAA**6124AM*+ furnace: 82*SB60090V21***AHRI reference: 21563000816.008.00300002.25EPA 3951284
CAA**6121AM*+ furnace: 926TC60100V21***AHRI reference: 21562994916.008.00302002.30EPA 3951286
CAA**6024AM*+ furnace: 935SB60100M21***AHRI reference: 21562936516.008.00300002.25EPA 3951299
CAA**6024AM*+ furnace: 935SB66100M21***AHRI reference: 21562938416.008.00296002.30EPA 3951320
CAA**6024AM*+ furnace: 986TD66100C21***AHRI reference: 21562941216.008.00300002.25EPA 3951336
CAA**6024AM*+ furnace: 986TD66120C24***AHRI reference: 21562942616.008.00298002.25EPA 3951351
CAA**6024AM*+ furnace: 926TC60080V21***AHRI reference: 21562944016.008.00300002.25EPA 3951366
CAA**6024AM*+ furnace: 926TC60100V21***AHRI reference: 21562945816.008.00298002.25EPA 3951455
CAA**6024AM*+ furnace: 926TC66100V21***AHRI reference: 21562947616.008.00296002.30EPA 3951473
CAA**6024AM*+ furnace: 926TC66120V24***AHRI reference: 21562949116.008.00300002.25EPA 3951486
CAA**6024AM*+ furnace: OVLAAB060154AHRI reference: 21562950716.008.00302002.25EPA 3951503
CAA**6121AM*+ furnace: 82*SB60090V21***AHRI reference: 21562956316.008.00300002.30EPA 3951518
CAA**6121AM*+ furnace: 83*SB48060M17***AHRI reference: 21562958916.008.00304002.25EPA 3951544

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →