BRYANT HEATING AND COOLING SYSTEMS / AIR-SOURCE HEAT PUMP

248TAN060**AA*

2-STAGE 18 SEER HP · source records, page 3

127 published source records · source checked Sep 21, 2026

SEER2 range15.5–17.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity54,000–58,000BTU/h

Each efficiency range summarizes published EPA records for 248TAN060**AA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 127 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.5–17.5127 / 127
EER2 · BTU/Wh11.7–13127 / 127
HSPF2 · BTU/Wh7.8–8.5127 / 127
Cooling capacity · BTU/h54,000–58,000127 / 127
Heating capacity at 47°F / 8.3°C · BTU/h56,500–61,500127 / 127
Heating capacity at 17°F / −8.3°C · BTU/h36,200–38,500127 / 127
Heating capacity at 5°F / −15°C · BTU/h29,600–31,800127 / 127
COP at 5°F / −15°C2.1–2.34127 / 127
Equipment / loop typeHP - Split System127 / 127
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)127 / 127
Compressor stagingTwo-stage127 / 127
Connected capabilityNo127 / 127

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CVAVA6021XMA*+ furnace: 935SB66100M21***AHRI reference: 21562727916.008.10302002.22EPA 3950117
CVAVA6021XMA*+ furnace: 926TC66100V21***AHRI reference: 21562735716.008.10302002.20EPA 3950132
CVAMA6021XMA*+ furnace: 82*SB66110V21***AHRI reference: 21562580816.008.10300002.24EPA 3950175
CVAMA6021XMA*+ furnace: 83*SB48060M17***AHRI reference: 21562582116.008.10300002.22EPA 3950186
CVAMA6021XMA*+ furnace: 83*SB60080M21***AHRI reference: 21562584016.008.10298002.24EPA 3950208
CVAMA6021XMA*+ furnace: 83*SB60100M21***AHRI reference: 21562585916.008.10304002.24EPA 3950224
CVAMA6021XMA*+ furnace: 88*TB60090C21***AHRI reference: 21562590616.008.10304002.22EPA 3950246
CVAMA6021XMA*+ furnace: 88*TB60110C21***AHRI reference: 21562592016.008.10304002.24EPA 3950260
CVAMA6021XMA*+ furnace: 82*TB66110V21***AHRI reference: 21562595016.008.10300002.24EPA 3950272
CVAMA6021XMA*+ furnace: 935CB66100C21***AHRI reference: 21562598216.008.10300002.24EPA 3950289
CVAMA6021XMA*+ furnace: 935SB60100M21***AHRI reference: 21562610216.008.10302002.22EPA 3950304
CVAMA6021XMA*+ furnace: 935SB66100M21***AHRI reference: 21562612116.008.10302002.22EPA 3950322
CVAMA6021XMA*+ furnace: 926TC66100V21***AHRI reference: 21562619916.008.10300002.24EPA 3950339
CVAMA6124XMA*+ furnace: 82*SB60090V21***AHRI reference: 21562649916.008.50318002.32EPA 3950352
CVAMA6124XMA*+ furnace: 83*SB60080M21***AHRI reference: 21562653816.008.50316002.32EPA 3950363
CVAMA6124XMA*+ furnace: 82*TB60090V21***AHRI reference: 21562663216.008.50318002.32EPA 3950383
CVAVA6121XMA*+ furnace: 82*SB60090V21***AHRI reference: 21562774516.008.10310002.22EPA 3950533
CVAVA6121XMA*+ furnace: 83*SB60080M21***AHRI reference: 21562777716.008.10306002.22EPA 3950547
CVAVA6121XMA*+ furnace: 83*SB60100M21***AHRI reference: 21562779616.008.10310002.20EPA 3950587
CVAVA6121XMA*+ furnace: 82*TB60090V21***AHRI reference: 21562785716.008.10310002.22EPA 3950654

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →