BRYANT HEATING AND COOLING SYSTEMS / AIR-SOURCE HEAT PUMP

248TAN048**AA*

2-STAGE 18 SEER HP · source records, page 7

417 published source records · source checked Sep 21, 2026

SEER2 range15.2–18BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity45,500–50,500BTU/h

Each efficiency range summarizes published EPA records for 248TAN048**AA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 417 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18417 / 417
EER2 · BTU/Wh11.7–13.5417 / 417
HSPF2 · BTU/Wh7.8–8.5417 / 417
Cooling capacity · BTU/h45,500–50,500417 / 417
Heating capacity at 47°F / 8.3°C · BTU/h48,500–52,500417 / 417
Heating capacity at 17°F / −8.3°C · BTU/h30,000–32,600417 / 417
Heating capacity at 5°F / −15°C · BTU/h23,800–26,600417 / 417
COP at 5°F / −15°C2.06–2.32417 / 417
Equipment / loop typeHP - Split System417 / 417
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)417 / 417
Compressor stagingTwo-stage417 / 417
Connected capabilityNo417 / 417

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CVAVA6121XMA*+ furnace: 83*CB60100C21***AHRI reference: 21572232317.008.00252002.24EPA 3982538 →
CVAVA6121XMA*+ furnace: 987TA66100C21***AHRI reference: 21572235117.008.00254002.10EPA 3982557 →
CVAVA6121XMA*+ furnace: 927TA60080V21***AHRI reference: 21572236517.008.00250002.10EPA 3982576 →
CVAVA6121XMA*+ furnace: 927TA60100V21***AHRI reference: 21572238117.008.00250002.12EPA 3982590 →
CVAVA6124XMA*+ furnace: 987TA66100C21***AHRI reference: 21572245417.008.00252002.12EPA 3982658 →
CVAVA6124XMA*+ furnace: 987TA66120C24***AHRI reference: 21572246817.008.00252002.12EPA 3982681 →
CVAVA6124XMA*+ furnace: 927TA60080V21***AHRI reference: 21572248217.008.00256002.10EPA 3982694 →
CVAVA6124XMA*+ furnace: 927TA60100V21***AHRI reference: 21572249817.008.00252002.12EPA 3982714 →
CVAMA4821XMA*+ furnace: 82*SB60090V21***AHRI reference: 21562290816.508.10244002.12EPA 3947313 →
CVAMA4821XMA*+ furnace: 82*SB66110V21***AHRI reference: 21562292116.508.10244002.14EPA 3947325 →
CVAMA4821XMA*+ furnace: 83*SB48060M17***AHRI reference: 21562293416.508.10246002.12EPA 3947340 →
CVAMA4821XMA*+ furnace: 83*SB60100M21***AHRI reference: 21562297216.508.10246002.12EPA 3947375 →
CVAMA4821XMA*+ furnace: 88*TB60090C21***AHRI reference: 21562300516.508.10244002.14EPA 3947411 →
CVAMA4821XMA*+ furnace: 88*TB60110C21***AHRI reference: 21562301916.508.10244002.12EPA 3947424 →
CVAMA4821XMA*+ furnace: 82*TB60090V21***AHRI reference: 21562303316.508.10244002.12EPA 3947437 →
CVAMA4821XMA*+ furnace: 82*TB66110V21***AHRI reference: 21562304916.508.10244002.14EPA 3947453 →
CVAMA4821XMA*+ furnace: 935SB60100M21***AHRI reference: 21562315516.508.10244002.12EPA 3947499 →
CVAMA4821XMA*+ furnace: 935SB66100M21***AHRI reference: 21562317416.508.10246002.12EPA 3947518 →
CVAMA4821XMA*+ furnace: 926TC66100V21***AHRI reference: 21562325216.508.10242002.12EPA 3947575 →
CVAMA4921XMA*+ furnace: 88*TB60070C21***AHRI reference: 21562334816.508.10256002.08EPA 3947670 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →