BRYANT HEATING AND COOLING SYSTEMS / AIR-SOURCE HEAT PUMP

248TAN048**AA*

2-STAGE 18 SEER HP · source records, page 18

417 published source records · source checked Sep 21, 2026

SEER2 range15.2–18BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity45,500–50,500BTU/h

Each efficiency range summarizes published EPA records for 248TAN048**AA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 417 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18417 / 417
EER2 · BTU/Wh11.7–13.5417 / 417
HSPF2 · BTU/Wh7.8–8.5417 / 417
Cooling capacity · BTU/h45,500–50,500417 / 417
Heating capacity at 47°F / 8.3°C · BTU/h48,500–52,500417 / 417
Heating capacity at 17°F / −8.3°C · BTU/h30,000–32,600417 / 417
Heating capacity at 5°F / −15°C · BTU/h23,800–26,600417 / 417
COP at 5°F / −15°C2.06–2.32417 / 417
Equipment / loop typeHP - Split System417 / 417
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)417 / 417
Compressor stagingTwo-stage417 / 417
Connected capabilityNo417 / 417

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CSAH*6012AM*+ furnace: 88*TB66135C24***AHRI reference: 21563421716.008.00250002.25EPA 3954179 →
CSAH*6012AM*+ furnace: 82*TB60090V21***AHRI reference: 21563424716.008.00250002.25EPA 3954192 →
CSAH*6012AM*+ furnace: 82*TB66110V21***AHRI reference: 21563426316.008.00250002.25EPA 3954209 →
CSAH*6012AM*+ furnace: 82*TB66135V24***AHRI reference: 21563428116.008.00250002.25EPA 3954226 →
CSAH*6012AM*+ furnace: 987MC66120C24***AHRI reference: 21563438716.008.00254002.20EPA 3954249 →
CSAH*6012AM*+ furnace: 926SB60080V21***AHRI reference: 21563442716.008.00252002.20EPA 3954263 →
CSAH*6012AM*+ furnace: 926SB60100V21***AHRI reference: 21563444016.008.00252002.20EPA 3954271 →
CSAH*6012AM*+ furnace: 926SB66120V24***AHRI reference: 21563445316.008.00252002.25EPA 3954286 →
CAA**6121AM*+ furnace: 83*CB60080C21***AHRI reference: 21572177116.008.00252002.26EPA 3981820 →
CAA**6121AM*+ furnace: 83*CB60100C21***AHRI reference: 21572178516.008.00254002.25EPA 3981838 →
CAA**6121AM*+ furnace: 927TA60080V21***AHRI reference: 21572179916.008.00256002.20EPA 3981855 →
CAA**6121AM*+ furnace: 927TA60100V21***AHRI reference: 21572181516.008.00256002.20EPA 3981867 →
CAA**4821AM*+ furnace: 927TA66100V21***AHRI reference: 21572173116.008.00248002.24EPA 3982220 →
CAA**6024AM*+ furnace: 83*CB60080C21***AHRI reference: 21572174416.008.00254002.20EPA 3982222 →
CAA**6024AM*+ furnace: 927TA66100V21***AHRI reference: 21572175816.008.00254002.22EPA 3982238 →
CAA**6124AM*+ furnace: 927TA66100V21***AHRI reference: 21572186016.008.00258002.20EPA 3982270 →
CVAMA6021XMA*+ furnace: 83*CB60100C21***AHRI reference: 21572201716.008.00246002.12EPA 3982429 →
CSAH*6012AM*+ furnace: 927TA66100V21***AHRI reference: 21571799416.008.00250002.25EPA 4000876 →
CSAH*6012AM*+ furnace: 987MC66100C21***AHRI reference: 21563437316.008.00252002.25EPA 4000889 →
CSAH*6012AM*+ furnace: 987MC60080C21***AHRI reference: 21563435916.008.00252002.20EPA 4000921 →