BRYANT HEATING AND COOLING SYSTEMS / AIR-SOURCE HEAT PUMP

248TAN036**AA*

2-STAGE 18 SEER HP · source records, page 13

274 published source records · source checked Sep 21, 2026

SEER2 range15.2–17BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity33,800–38,000BTU/h

Each efficiency range summarizes published EPA records for 248TAN036**AA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 274 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–17274 / 274
EER2 · BTU/Wh11.7–13274 / 274
HSPF2 · BTU/Wh7.8–8.5274 / 274
Cooling capacity · BTU/h33,800–38,000274 / 274
Heating capacity at 47°F / 8.3°C · BTU/h37,200–39,000274 / 274
Heating capacity at 17°F / −8.3°C · BTU/h23,000–24,200274 / 274
Heating capacity at 5°F / −15°C · BTU/h17,500–19,600274 / 274
COP at 5°F / −15°C1.78–2.48274 / 274
Equipment / loop typeHP - Split System274 / 274
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)274 / 274
Compressor stagingTwo-stage274 / 274
Connected capabilityNo274 / 274

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CSAH*3612AM*+ furnace: 83*SB60080M21***AHRI reference: 21564000715.207.80188002.26EPA 3956500
CSAH*3612AM*+ furnace: 926TC66100V21***AHRI reference: 21564067415.207.80190002.24EPA 3956517
CSAH*4212AM*+ furnace: 83*CA60080C21***AHRI reference: 21564078315.208.10192002.24EPA 3956532
CSAH*4212AM*+ furnace: 82*SB60090V21***AHRI reference: 21564089015.207.80191002.26EPA 3956549
CSAH*4212AM*+ furnace: 82*SB66110V21***AHRI reference: 21564090915.207.80190002.26EPA 3956564
CSAH*4812AM*+ furnace: 88*TB60110C21***AHRI reference: 21564235615.208.10191002.26EPA 3956573
CSAH*4812AM*+ furnace: 88*TB66135C24***AHRI reference: 21564237815.208.10190002.26EPA 3956582
CSAH*4812AM*+ furnace: 82*TB60090V21***AHRI reference: 21564243615.208.10192002.24EPA 3956605
CSAH*4812AM*+ furnace: 82*TB66135V24***AHRI reference: 21564247015.208.10190002.26EPA 3956609
CSAH*4812AM*+ furnace: 935CB66100C21***AHRI reference: 21564249215.208.10190002.26EPA 3956622
CSAH*4812AM*+ furnace: 987MC66100C21***AHRI reference: 21564254815.208.10191002.26EPA 3956639
CSAH*4812AM*+ furnace: 926SB66120V24***AHRI reference: 21564264115.207.80190002.26EPA 3956650
CSAH*4812AM*+ furnace: 935SB60080M21***AHRI reference: 21564269115.207.80192002.26EPA 3956672
CSAH*4812AM*+ furnace: 935SB66100M21***AHRI reference: 21564274715.208.10190002.26EPA 3956682
CSAH*4212AM*+ furnace: 83*SB48060M17***AHRI reference: 21564097815.207.80190002.26EPA 3956709
CSAH*4212AM*+ furnace: 82*TB60090V21***AHRI reference: 21564130015.207.80191002.26EPA 3956742
CSAH*4212AM*+ furnace: 82*TB66110V21***AHRI reference: 21564132415.207.80190002.26EPA 3956758
CSAH*4812AM*+ furnace: 986TD66100C21***AHRI reference: 21564281015.208.10191002.26EPA 3956775
CSAH*4812AM*+ furnace: 926TC60100V21***AHRI reference: 21564290915.208.10191002.26EPA 3956793
CSAH*4812AM*+ furnace: 926TC66100V21***AHRI reference: 21564293615.208.10191002.26EPA 3956816

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →