248TAN036**AA*
2-STAGE 18 SEER HP
274 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for 248TAN036**AA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 274 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–17 | 274 / 274 |
| EER2 · BTU/Wh | 11.7–13 | 274 / 274 |
| HSPF2 · BTU/Wh | 7.8–8.5 | 274 / 274 |
| Cooling capacity · BTU/h | 33,800–38,000 | 274 / 274 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 37,200–39,000 | 274 / 274 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 23,000–24,200 | 274 / 274 |
| Heating capacity at 5°F / −15°C · BTU/h | 17,500–19,600 | 274 / 274 |
| COP at 5°F / −15°C | 1.78–2.48 | 274 / 274 |
| Equipment / loop type | HP - Split System | 274 / 274 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 274 / 274 |
| Compressor staging | Two-stage | 274 / 274 |
| Connected capability | No | 274 / 274 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
FG5ANBD60L*AHRI reference: 215628939 | 17.00 | 8.50 | 18600 | 2.48 | EPA 3950874 → |
PF5TNBD60L*AHRI reference: 215628940 | 17.00 | 8.50 | 18600 | 2.48 | EPA 3950875 → |
FT5ANBD60L*AHRI reference: 215628938 | 17.00 | 8.50 | 18600 | 2.48 | EPA 3950876 → |
FG5ANXC48L*AHRI reference: 215628885 | 16.50 | 8.10 | 18700 | 2.30 | EPA 3950425 → |
FT5AN(B,X)C48L*AHRI reference: 215628884 | 16.50 | 8.10 | 18700 | 2.30 | EPA 3950426 → |
PF5TNXC48L*AHRI reference: 215628886 | 16.50 | 8.10 | 18700 | 2.30 | EPA 3950428 → |
FT5BD4821X*AHRI reference: 218695407 | 16.50 | 8.10 | 18400 | 2.24 | EPA 4683420 → |
CVAMA4821XMA*+ furnace: 83*SB60080M21***AHRI reference: 215619534 | 16.00 | 8.00 | 17500 | 1.90 | EPA 3946331 → |
CVAMA4921XMA*+ furnace: 82*SB60090V21***AHRI reference: 215619885 | 16.00 | 8.00 | 17900 | 1.90 | EPA 3946541 → |
CVAMA4921XMA*+ furnace: 83*SB60080M21***AHRI reference: 215619898 | 16.00 | 8.00 | 17700 | 1.95 | EPA 3946553 → |
CVAMA4921XMA*+ furnace: 82*TB60090V21***AHRI reference: 215619971 | 16.00 | 8.00 | 17900 | 1.90 | EPA 3946626 → |
CVAMA4921XMA*+ furnace: 935CB66100C21***AHRI reference: 215620001 | 16.00 | 8.00 | 17900 | 1.95 | EPA 3946642 → |
CVAMA4921XMA*+ furnace: 986TD60080C21***AHRI reference: 215620042 | 16.00 | 7.80 | 17900 | 1.80 | EPA 3946657 → |
CVAMA4921XMA*+ furnace: 926TC60100V21***AHRI reference: 215620078 | 16.00 | 8.00 | 17900 | 1.90 | EPA 3946671 → |
CVAVA3817XMA*+ furnace: 82*SB48090V17***AHRI reference: 215621310 | 16.00 | 8.00 | 17600 | 1.90 | EPA 3946861 → |
CVAVA3817XMA*+ furnace: 83*SB36040M17***AHRI reference: 215621323 | 16.00 | 8.00 | 17600 | 1.85 | EPA 3946875 → |
CVAVA3817XMA*+ furnace: 83*SB48060M17***AHRI reference: 215621342 | 16.00 | 8.00 | 17600 | 1.90 | EPA 3946895 → |
CVAVA3817XMA*+ furnace: 88*TB48090C17***AHRI reference: 215621403 | 16.00 | 7.80 | 17600 | 1.80 | EPA 3946929 → |
CVAVA3817XMA*+ furnace: 82*TB48090V17***AHRI reference: 215621443 | 16.00 | 8.00 | 17600 | 1.90 | EPA 3946970 → |
CAA**3721AM*+ furnace: 82*SB66110V21***AHRI reference: 215635684 | 16.00 | 8.10 | 19400 | 2.24 | EPA 3954584 → |