BRYANT HEATING AND COOLING SYSTEMS / AIR-SOURCE HEAT PUMP

248TAN036**AA*

2-STAGE 18 SEER HP

274 published source records · source checked Sep 21, 2026

SEER2 range15.2–17BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity33,800–38,000BTU/h

Each efficiency range summarizes published EPA records for 248TAN036**AA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 274 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–17274 / 274
EER2 · BTU/Wh11.7–13274 / 274
HSPF2 · BTU/Wh7.8–8.5274 / 274
Cooling capacity · BTU/h33,800–38,000274 / 274
Heating capacity at 47°F / 8.3°C · BTU/h37,200–39,000274 / 274
Heating capacity at 17°F / −8.3°C · BTU/h23,000–24,200274 / 274
Heating capacity at 5°F / −15°C · BTU/h17,500–19,600274 / 274
COP at 5°F / −15°C1.78–2.48274 / 274
Equipment / loop typeHP - Split System274 / 274
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)274 / 274
Compressor stagingTwo-stage274 / 274
Connected capabilityNo274 / 274

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
FG5ANBD60L*AHRI reference: 21562893917.008.50186002.48EPA 3950874 →
PF5TNBD60L*AHRI reference: 21562894017.008.50186002.48EPA 3950875 →
FT5ANBD60L*AHRI reference: 21562893817.008.50186002.48EPA 3950876 →
FG5ANXC48L*AHRI reference: 21562888516.508.10187002.30EPA 3950425 →
FT5AN(B,X)C48L*AHRI reference: 21562888416.508.10187002.30EPA 3950426 →
PF5TNXC48L*AHRI reference: 21562888616.508.10187002.30EPA 3950428 →
FT5BD4821X*AHRI reference: 21869540716.508.10184002.24EPA 4683420 →
CVAMA4821XMA*+ furnace: 83*SB60080M21***AHRI reference: 21561953416.008.00175001.90EPA 3946331 →
CVAMA4921XMA*+ furnace: 82*SB60090V21***AHRI reference: 21561988516.008.00179001.90EPA 3946541 →
CVAMA4921XMA*+ furnace: 83*SB60080M21***AHRI reference: 21561989816.008.00177001.95EPA 3946553 →
CVAMA4921XMA*+ furnace: 82*TB60090V21***AHRI reference: 21561997116.008.00179001.90EPA 3946626 →
CVAMA4921XMA*+ furnace: 935CB66100C21***AHRI reference: 21562000116.008.00179001.95EPA 3946642 →
CVAMA4921XMA*+ furnace: 986TD60080C21***AHRI reference: 21562004216.007.80179001.80EPA 3946657 →
CVAMA4921XMA*+ furnace: 926TC60100V21***AHRI reference: 21562007816.008.00179001.90EPA 3946671 →
CVAVA3817XMA*+ furnace: 82*SB48090V17***AHRI reference: 21562131016.008.00176001.90EPA 3946861 →
CVAVA3817XMA*+ furnace: 83*SB36040M17***AHRI reference: 21562132316.008.00176001.85EPA 3946875 →
CVAVA3817XMA*+ furnace: 83*SB48060M17***AHRI reference: 21562134216.008.00176001.90EPA 3946895 →
CVAVA3817XMA*+ furnace: 88*TB48090C17***AHRI reference: 21562140316.007.80176001.80EPA 3946929 →
CVAVA3817XMA*+ furnace: 82*TB48090V17***AHRI reference: 21562144316.008.00176001.90EPA 3946970 →
CAA**3721AM*+ furnace: 82*SB66110V21***AHRI reference: 21563568416.008.10194002.24EPA 3954584 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →