BRYANT HEATING AND COOLING SYSTEMS / AIR-SOURCE HEAT PUMP

248TAN024**AA*

2-STAGE 18 SEER HP · source records, page 7

541 published source records · source checked Sep 21, 2026

SEER2 range15.2–18.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity22,200–25,000BTU/h

Each efficiency range summarizes published EPA records for 248TAN024**AA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 541 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18.5541 / 541
EER2 · BTU/Wh11.5–14541 / 541
HSPF2 · BTU/Wh7.8–8.5541 / 541
Cooling capacity · BTU/h22,200–25,000541 / 541
Heating capacity at 47°F / 8.3°C · BTU/h24,000–25,400541 / 541
Heating capacity at 17°F / −8.3°C · BTU/h14,100–15,000541 / 541
Heating capacity at 5°F / −15°C · BTU/h10,700–11,500541 / 541
COP at 5°F / −15°C1.9–2.24541 / 541
Equipment / loop typeHP - Split System541 / 541
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)541 / 541
Compressor stagingTwo-stage541 / 541
Connected capabilityNo541 / 541

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CAA**3721AM*+ furnace: 82*TB60090V21***AHRI reference: 21564810617.508.10111002.10EPA 3960669 →
CAA**3721AM*+ furnace: 82*SB48070V17***AHRI reference: 21564776917.508.10111002.10EPA 3960753 →
CAA**3721AM*+ furnace: 82*SB60090V21***AHRI reference: 21564780817.508.10111002.10EPA 3960783 →
CAA**3721AM*+ furnace: 83*SB60100M21***AHRI reference: 21564792317.508.10111002.10EPA 3960999 →
CAA**3721AM*+ furnace: 88*TB36045C17***AHRI reference: 21564794917.508.10112002.08EPA 3961013 →
CAA**3721AM*+ furnace: 88*TB60070C21***AHRI reference: 21564798917.508.10111002.10EPA 3961038 →
CAA**3721AM*+ furnace: 986TD66100C21***AHRI reference: 21564859617.508.10111002.10EPA 3961069 →
CAA**3721AM*+ furnace: 935CB48060C17***AHRI reference: 21564815417.508.10111002.10EPA 3961284 →
CAA**3721AM*+ furnace: 935CB60080C21***AHRI reference: 21564817417.508.10112002.10EPA 3961294 →
CAA**3721AM*+ furnace: 935CB66100C21***AHRI reference: 21564819417.508.10111002.10EPA 3961301 →
CAA**3721AM*+ furnace: 987MC42060C17***AHRI reference: 21564821517.508.10112002.10EPA 3961321 →
CAA**3721AM*+ furnace: 987MC60060C21***AHRI reference: 21564823617.508.50112002.10EPA 3961327 →
CAA**3721AM*+ furnace: 987MC42080C17***AHRI reference: 21564825617.508.10112002.08EPA 3961342 →
CAA**3721AM*+ furnace: 987MC60080C21***AHRI reference: 21564827617.508.10111002.10EPA 3961361 →
CAA**3721AM*+ furnace: 987MC66100C21***AHRI reference: 21564829717.508.10111002.10EPA 3961381 →
CAA**3721AM*+ furnace: 926SB48080V17***AHRI reference: 21564835617.508.10112002.08EPA 3961416 →
CAA**3721AM*+ furnace: 935SB36040M17***AHRI reference: 21564841417.508.10112002.08EPA 3961456 →
CAA**3721AM*+ furnace: 935SB48060M17***AHRI reference: 21564844117.508.10111002.10EPA 3961471 →
CAA**3721AM*+ furnace: 935SB60080M21***AHRI reference: 21564846617.508.10111002.10EPA 3961488 →
CAA**3721AM*+ furnace: 986TD42060C17***AHRI reference: 21564853617.508.10112002.10EPA 3961649 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.