BRYANT HEATING AND COOLING SYSTEMS / AIR-SOURCE HEAT PUMP

248TAN024**AA*

2-STAGE 18 SEER HP · source records, page 17

541 published source records · source checked Sep 21, 2026

SEER2 range15.2–18.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity22,200–25,000BTU/h

Each efficiency range summarizes published EPA records for 248TAN024**AA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 541 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18.5541 / 541
EER2 · BTU/Wh11.5–14541 / 541
HSPF2 · BTU/Wh7.8–8.5541 / 541
Cooling capacity · BTU/h22,200–25,000541 / 541
Heating capacity at 47°F / 8.3°C · BTU/h24,000–25,400541 / 541
Heating capacity at 17°F / −8.3°C · BTU/h14,100–15,000541 / 541
Heating capacity at 5°F / −15°C · BTU/h10,700–11,500541 / 541
COP at 5°F / −15°C1.9–2.24541 / 541
Equipment / loop typeHP - Split System541 / 541
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)541 / 541
Compressor stagingTwo-stage541 / 541
Connected capabilityNo541 / 541

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CSAH*3012AM*+ furnace: 82*SB48070V17***AHRI reference: 21565033516.507.80111002.08EPA 3963034
CSAH*3012AM*+ furnace: 82*SB48090V17***AHRI reference: 21565035516.507.80110002.08EPA 3963044
CSAH*3012AM*+ furnace: 82*SB60090V21***AHRI reference: 21565037316.508.00112002.06EPA 3963055
CSAH*3012AM*+ furnace: 82*SB66110V21***AHRI reference: 21565039216.508.00110002.08EPA 3963078
CSAH*3012AM*+ furnace: 83*SB36040M17***AHRI reference: 21565043216.508.00110002.08EPA 3963099
CSAH*3012AM*+ furnace: 83*SB48060M17***AHRI reference: 21565046216.507.80111002.08EPA 3963112
CSAH*3012AM*+ furnace: 83*SB60080M21***AHRI reference: 21565048816.507.80110002.08EPA 3963137
CSAH*3012AM*+ furnace: 82*TB36045V14***AHRI reference: 21565070916.507.80111002.08EPA 3963183
CSAH*3012AM*+ furnace: 82*TB36070V14***AHRI reference: 21565073716.508.00111002.08EPA 3963197
CSAH*3012AM*+ furnace: 82*TB48070V17***AHRI reference: 21565075216.507.80110002.08EPA 3963205
CSAH*3012AM*+ furnace: 88*TB36070C14***AHRI reference: 21565056416.508.00110002.06EPA 3963241
CSAH*3012AM*+ furnace: 88*TB48070C17***AHRI reference: 21565058416.507.80110002.08EPA 3963252
CSAH*3012AM*+ furnace: 987MC42080C17***AHRI reference: 21565095416.507.80111002.08EPA 3963320
CSAH*3012AM*+ furnace: 987MC66100C21***AHRI reference: 21565099616.507.80110002.08EPA 3963339
CSAH*3012AM*+ furnace: 986TD42080C17***AHRI reference: 21565136516.508.00111002.06EPA 3963516
CSAH*3012AM*+ furnace: 926SB60080V21***AHRI reference: 21565113416.508.00111002.06EPA 3963611
CSAH*3012AM*+ furnace: 926SB60100V21***AHRI reference: 21565115316.507.80110002.08EPA 3963630
CSAH*3012AM*+ furnace: 926SB66120V24***AHRI reference: 21565117116.507.80110002.08EPA 3963649
CSAH*3012AM*+ furnace: 935SB48060M17***AHRI reference: 21565121916.507.80110002.08EPA 3963651
CSAH*3012AM*+ furnace: 935SB60080M21***AHRI reference: 21565124716.508.00112002.06EPA 3963669