BRYANT HEATING AND COOLING SYSTEMS / AIR-SOURCE HEAT PUMP

246SAN024**AA*

PREFERRED 16 SEER2 HP · source records, page 8

199 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity22,200–24,400BTU/h

Each efficiency range summarizes published EPA records for 246SAN024**AA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 199 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.5199 / 199
EER2 · BTU/Wh11.7–13199 / 199
HSPF2 · BTU/Wh7.8–8.5199 / 199
Cooling capacity · BTU/h22,200–24,400199 / 199
Heating capacity at 47°F / 8.3°C · BTU/h21,600–24,000199 / 199
Heating capacity at 17°F / −8.3°C · BTU/h14,200–15,200199 / 199
Heating capacity at 5°F / −15°C · BTU/h10,800–11,900199 / 199
COP at 5°F / −15°C1.96–2.26199 / 199
Equipment / loop typeHP - Split System199 / 199
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)199 / 199
Compressor stagingSingle stage199 / 199
Connected capabilityNo199 / 199

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CAA**3721AM*+ furnace: 88*TB36045C17***AHRI reference: 21413313215.207.80117002.12EPA 3400145
CAA**3721AM*+ furnace: 935SB36040M17***AHRI reference: 21413321915.207.80118002.10EPA 3400210
CAA**3717AM*+ furnace: 8(0,1)*SB42045M17***AHRI reference: 21413262515.207.80114002.08EPA 3400229
CAA**3717AM*+ furnace: 88*TB36045C17***AHRI reference: 21413268015.207.80114002.06EPA 3400258
CAA**2517AM*+ furnace: 926TC36060V14***AHRI reference: 21413102115.207.80115002.08EPA 3400282
FJ5AN*B30L*AHRI reference: 21417972315.207.80111002.06EPA 3404518
PF5MN*B30L*AHRI reference: 21417972415.207.80111002.06EPA 3404520
CAA**2517AM*+ furnace: 926SB48060V17***AHRI reference: 21419816815.207.80114002.10EPA 3404944
CAA**2517AM*+ furnace: 82*SB48090V17***AHRI reference: 21419743615.207.80113002.12EPA 3404974
CAA**2517AM*+ furnace: 8(0,1)*SB36045M14***AHRI reference: 21419723815.207.80114002.10EPA 3405131
CAA**2517AM*+ furnace: 8(0,1)*SB42045M17***AHRI reference: 21419727015.207.80115002.10EPA 3405150
CAA**2517AM*+ furnace: 8(0,1)*SB48070M17***AHRI reference: 21419729815.207.80113002.12EPA 3405180
CAA**3617AM*+ furnace: 8(0,1)*SB42090M17***AHRI reference: 21419898715.207.80110002.02EPA 3405369
CAA**2517AM*+ furnace: 935SB48060M17***AHRI reference: 21419825715.207.80113002.12EPA 3405393
CAA**2517AM*+ furnace: 82*SB48070V17***AHRI reference: 21419741115.207.80113002.10EPA 3405449
CAA**2517AM*+ furnace: 926TC48060V17***AHRI reference: 21419849615.207.80114002.10EPA 3405603
CAA**2517AM*+ furnace: 82*TB48070V17***AHRI reference: 21419766315.207.80114002.10EPA 3405682
CAA**2517AM*+ furnace: 82*TB48090V17***AHRI reference: 21419769115.207.80113002.12EPA 3405709
CAA**2517AM*+ furnace: 926TC48080V17***AHRI reference: 21419852915.207.80114002.10EPA 3405748
CAA**2517AM*+ furnace: 916SA48080M17***AHRI reference: 21419805515.207.80114002.10EPA 3405793