BRYANT HEATING AND COOLING SYSTEMS / AIR-SOURCE HEAT PUMP

246SAN024**AA*

PREFERRED 16 SEER2 HP · source records, page 3

199 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity22,200–24,400BTU/h

Each efficiency range summarizes published EPA records for 246SAN024**AA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 199 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.5199 / 199
EER2 · BTU/Wh11.7–13199 / 199
HSPF2 · BTU/Wh7.8–8.5199 / 199
Cooling capacity · BTU/h22,200–24,400199 / 199
Heating capacity at 47°F / 8.3°C · BTU/h21,600–24,000199 / 199
Heating capacity at 17°F / −8.3°C · BTU/h14,200–15,200199 / 199
Heating capacity at 5°F / −15°C · BTU/h10,800–11,900199 / 199
COP at 5°F / −15°C1.96–2.26199 / 199
Equipment / loop typeHP - Split System199 / 199
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)199 / 199
Compressor stagingSingle stage199 / 199
Connected capabilityNo199 / 199

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
FJ5AN*B36L*AHRI reference: 21417976715.507.80114002.10EPA 3404557 →
FT5ANXB24L*AHRI reference: 21417984915.507.80112002.08EPA 3404618 →
FG5ANXB24L*AHRI reference: 21417985015.507.80112002.08EPA 3404619 →
PF5TNXB24L*AHRI reference: 21417985115.507.80112002.08EPA 3404622 →
CAA**2517AM*+ furnace: 916SA48060M17***AHRI reference: 21419802115.507.80114002.10EPA 3405036 →
CAA**2517AM*+ furnace: 88*TB48090C17***AHRI reference: 21419759615.507.80114002.10EPA 3405464 →
CAA**2517AM*+ furnace: 986TD42080C17***AHRI reference: 21419837015.507.80113002.10EPA 3405539 →
CAA**2517AM*+ furnace: 986TD42060C17***AHRI reference: 21419834315.507.80114002.10EPA 3405547 →
CAA**2517AM*+ furnace: 88*TB36045C17***AHRI reference: 21419754215.507.80115002.10EPA 3405597 →
CAA**2517AM*+ furnace: 88*TB48070C17***AHRI reference: 21419756915.507.80114002.10EPA 3405644 →
CAA**2517AM*+ furnace: 987MC42060C17***AHRI reference: 21419781115.507.80115002.10EPA 3405813 →
CAA**2517AM*+ furnace: 935CB48060C17***AHRI reference: 21419773015.507.80113002.10EPA 3405821 →
CAA**2517AM*+ furnace: 987MC42080C17***AHRI reference: 21419783815.507.80115002.12EPA 3405976 →
CAA**3717AM*+ furnace: 8(0,1)*SB48070M17***AHRI reference: 21419978915.507.80113002.08EPA 3406280 →
CVAMA3217XMA*+ furnace: 926SB48080V17***AHRI reference: 21420470115.507.80113001.98EPA 3406295 →
CVAVA3117XMA*+ furnace: 935SB48060M17***AHRI reference: 21420559815.507.80113001.98EPA 3406412 →
CAA**3721AM*+ furnace: 88*TB60110C21***AHRI reference: 21420195215.507.80116002.14EPA 3406419 →
CAA**3721AM*+ furnace: 987MC42060C17***AHRI reference: 21420230115.507.80117002.12EPA 3406454 →
CAA**3721AM*+ furnace: 935SB60080M21***AHRI reference: 21420283515.507.80116002.14EPA 3406516 →
CVAVA3817XMA*+ furnace: 926TC48080V17***AHRI reference: 21420777615.507.80113001.98EPA 3406594 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →