BRYANT HEATING AND COOLING SYSTEMS / AIR-SOURCE HEAT PUMP

246SAN024**AA*

PREFERRED 16 SEER2 HP · source records, page 10

199 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity22,200–24,400BTU/h

Each efficiency range summarizes published EPA records for 246SAN024**AA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 199 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.5199 / 199
EER2 · BTU/Wh11.7–13199 / 199
HSPF2 · BTU/Wh7.8–8.5199 / 199
Cooling capacity · BTU/h22,200–24,400199 / 199
Heating capacity at 47°F / 8.3°C · BTU/h21,600–24,000199 / 199
Heating capacity at 17°F / −8.3°C · BTU/h14,200–15,200199 / 199
Heating capacity at 5°F / −15°C · BTU/h10,800–11,900199 / 199
COP at 5°F / −15°C1.96–2.26199 / 199
Equipment / loop typeHP - Split System199 / 199
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)199 / 199
Compressor stagingSingle stage199 / 199
Connected capabilityNo199 / 199

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CAA**3721AM*+ furnace: 916SA48080M17***AHRI reference: 21420250515.207.80116002.12EPA 3407981
CAA**3717AM*+ furnace: 82*SB36070V14***AHRI reference: 21419995915.207.80112002.08EPA 3408007
CAA**3717AM*+ furnace: 82*SB48070V17***AHRI reference: 21419998415.207.80113002.08EPA 3408032
CAA**3721AM*+ furnace: 82*SB48070V17***AHRI reference: 21420165715.207.80115002.14EPA 3408182
CAA**3717AM*+ furnace: 926SB48060V17***AHRI reference: 21420090415.207.80114002.08EPA 3408320
CAA**3717AM*+ furnace: 926SB48080V17***AHRI reference: 21420092915.207.80114002.08EPA 3408346
CAA**3721AM*+ furnace: 82*SB48090V17***AHRI reference: 21420168315.207.80116002.14EPA 3408381
CAA**3721AM*+ furnace: 926SB48080V17***AHRI reference: 21420272515.207.80116002.12EPA 3408695
CAA**3721AM*+ furnace: 926SB48060V17***AHRI reference: 21420270015.207.80118002.12EPA 3408707
CAA**2517AM*+ furnace: 83*CA36040C17***AHRI reference: 21421028315.207.80112002.12EPA 3409647
CAA**2517AM*+ furnace: 8(0,1)*SB36070M14***AHRI reference: 21421034415.207.80113002.12EPA 3409733
CAA**2517AM*+ furnace: 82*SB36070V14***AHRI reference: 21421043815.207.80113002.12EPA 3410090
CAA**2517AM*+ furnace: 83*SA36040E17***AHRI reference: 21421046315.207.80110002.08EPA 3410357
CAA**2517AM*+ furnace: 82*TB36045V14***AHRI reference: 21421068515.207.80113002.12EPA 3410930
CAA**2517AM*+ furnace: 912SE48080M17***AHRI reference: 21421079115.207.80114002.12EPA 3410992
CAA**2517AM*+ furnace: 82*TB36070V14***AHRI reference: 21421071515.207.80113002.12EPA 3411012
FMA5L30**AL*AHRI reference: 21442400715.208.10119002.16EPA 3425288
F55AA*B30L*AHRI reference: 21646376215.207.80111002.06EPA 3847000
FM(C,U)5S24**AL*AHRI reference: 21845224415.207.80111002.00EPA 4624520

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →