BRYANT HEATING AND COOLING SYSTEMS / AIR-SOURCE HEAT PUMP

235SAN036**AA*

LEGACY 15 SEER2 HP

33 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8BTU/Wh
Cooling capacity33,800–36,800BTU/h

Each efficiency range summarizes published EPA records for 235SAN036**AA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 33 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–1633 / 33
EER2 · BTU/Wh11.7–1333 / 33
HSPF2 · BTU/Wh7.8–833 / 33
Cooling capacity · BTU/h33,800–36,80033 / 33
Heating capacity at 47°F / 8.3°C · BTU/h33,200–36,40033 / 33
Heating capacity at 17°F / −8.3°C · BTU/h21,000–22,80033 / 33
Heating capacity at 5°F / −15°C · BTU/h16,100–18,10033 / 33
COP at 5°F / −15°C2–2.2233 / 33
Equipment / loop typeHP - Split System33 / 33
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)33 / 33
Compressor stagingSingle stage33 / 33
Connected capabilityNo33 / 33

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
FEVA0048**+NAVA54801CKAHRI reference: 21705163416.008.00174002.18EPA 4001103 →
FT5AN(B,X)C48L*AHRI reference: 21417992615.507.80167002.18EPA 3404449 →
FG5ANXC48L*AHRI reference: 21417992715.507.80167002.18EPA 3404450 →
PF5TNXC48L*AHRI reference: 21417992815.507.80167002.18EPA 3404451 →
PF5MN*C48L*AHRI reference: 21418017215.507.80174002.18EPA 3404788 →
FJ5AN*C48L*AHRI reference: 21418017115.507.80174002.18EPA 3404790 →
FEVB0048**+NAVA54801CKAHRI reference: 21427759315.507.80174002.22EPA 3415683 →
FMA5X36**AL*AHRI reference: 21442428615.507.80170002.00EPA 3425176 →
F55AA*C48L*AHRI reference: 21646399815.507.80174002.18EPA 3846920 →
CAA**4821AM*+ furnace: 83*SB48060M17***AHRI reference: 21414162815.207.80176002.18EPA 3400312 →
CAA**4821AM*+ furnace: 935SB66100M21***AHRI reference: 21414263115.207.80176002.18EPA 3400436 →
CAA**4821AM*+ furnace: 88*TB60110C21***AHRI reference: 21414183215.207.80175002.18EPA 3400469 →
CAA**4821AM*+ furnace: 82*TB60090V21***AHRI reference: 21414194115.207.80175002.18EPA 3400607 →
CAA**4821AM*+ furnace: 926TC66100V21***AHRI reference: 21414285715.207.80175002.20EPA 3400662 →
CAA**4821AM*+ furnace: 8(0,1)*SB60090M21***AHRI reference: 21414133615.207.80175002.18EPA 3400762 →
CAA**4321AM*+ furnace: 912SE60100M21***AHRI reference: 21414050915.207.80179002.20EPA 3400784 →
CAA**4821AM*+ furnace: 8(0,1)*SB60110M21***AHRI reference: 21414136615.207.80176002.20EPA 3400835 →
CAA**4821AM*+ furnace: 912SE60100M21***AHRI reference: 21414225515.207.80176002.18EPA 3400867 →
CAA**4821AM*+ furnace: 82*SB60090V21***AHRI reference: 21414145015.207.80175002.18EPA 3400916 →
CVAMA4421XMA*+ furnace: 83*SA36040E17***AHRI reference: 21414304415.207.80181002.14EPA 3401008 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →