BRYANT HEATING AND COOLING SYSTEMS / AIR-SOURCE HEAT PUMP

235SAN024**AA*

LEGACY 15 SEER2 HP · source records, page 5

199 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity22,200–24,400BTU/h

Each efficiency range summarizes published EPA records for 235SAN024**AA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 199 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.5199 / 199
EER2 · BTU/Wh11.7–13199 / 199
HSPF2 · BTU/Wh7.8–8.5199 / 199
Cooling capacity · BTU/h22,200–24,400199 / 199
Heating capacity at 47°F / 8.3°C · BTU/h21,600–24,000199 / 199
Heating capacity at 17°F / −8.3°C · BTU/h14,200–15,200199 / 199
Heating capacity at 5°F / −15°C · BTU/h10,800–11,900199 / 199
COP at 5°F / −15°C1.96–2.26199 / 199
Equipment / loop typeHP - Split System199 / 199
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)199 / 199
Compressor stagingSingle stage199 / 199
Connected capabilityNo199 / 199

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CAA**3717AM*+ furnace: 912SE48080M17***AHRI reference: 21420071915.507.80113002.10EPA 3407689 →
CVAMA3217XMA*+ furnace: 926TC48080V17***AHRI reference: 21420482015.507.80113001.98EPA 3407728 →
CAA**3721AM*+ furnace: 916SA66100M21***AHRI reference: 21420256615.507.80116002.14EPA 3407894 →
CVAVA3117XMA*+ furnace: 8(0,1)*SB48070M17***AHRI reference: 21420497615.507.80113001.98EPA 3408056 →
CAA**3717AM*+ furnace: 916SA48080M17***AHRI reference: 21420081715.507.80113002.08EPA 3408085 →
CVAMA3117XMA*+ furnace: 935SB48060M17***AHRI reference: 21420416315.507.80113001.98EPA 3408131 →
CAA**3717AM*+ furnace: 83*SB36040M17***AHRI reference: 21420007215.507.80113002.10EPA 3408244 →
CAA**3721AM*+ furnace: 82*SB60090V21***AHRI reference: 21420170715.507.80116002.14EPA 3408404 →
CAA**3721AM*+ furnace: 83*SB60100M21***AHRI reference: 21420173215.507.80116002.14EPA 3408430 →
CVAVA3817XMA*+ furnace: 926SB48060V17***AHRI reference: 21420760215.507.80114001.98EPA 3408485 →
CVAVA3817XMA*+ furnace: 926SB48080V17***AHRI reference: 21420762715.507.80113001.98EPA 3408500 →
CAA**3721AM*+ furnace: 88*TB60070C21***AHRI reference: 21420189715.507.80116002.14EPA 3408567 →
CAA**3721AM*+ furnace: 88*TB48090C17***AHRI reference: 21420192415.507.80115002.14EPA 3408600 →
CAA**3721AM*+ furnace: 88*TB48070C17***AHRI reference: 21420187015.507.80115002.14EPA 3408618 →
CAA**3717AM*+ furnace: 88*TB36070C14***AHRI reference: 21420015815.507.80112002.08EPA 3408629 →
CAA**3717AM*+ furnace: 88*TB48070C17***AHRI reference: 21420018515.507.80113002.08EPA 3408657 →
CAA**3717AM*+ furnace: 88*TB48090C17***AHRI reference: 21420021215.507.80113002.08EPA 3408684 →
CAA**3721AM*+ furnace: 926SB60100V21***AHRI reference: 21420274915.507.80116002.14EPA 3408714 →
CVAMA3117XMA*+ furnace: 8(0,1)*SB48070M17***AHRI reference: 21420348315.507.80113001.98EPA 3408735 →
CVAVA3117XMA*+ furnace: 82*TB48070V17***AHRI reference: 21420517615.507.80113001.98EPA 3408774 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.