235SAN024**AA*
LEGACY 15 SEER2 HP · source records, page 3
199 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for 235SAN024**AA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 199 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–16.5 | 199 / 199 |
| EER2 · BTU/Wh | 11.7–13 | 199 / 199 |
| HSPF2 · BTU/Wh | 7.8–8.5 | 199 / 199 |
| Cooling capacity · BTU/h | 22,200–24,400 | 199 / 199 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 21,600–24,000 | 199 / 199 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 14,200–15,200 | 199 / 199 |
| Heating capacity at 5°F / −15°C · BTU/h | 10,800–11,900 | 199 / 199 |
| COP at 5°F / −15°C | 1.96–2.26 | 199 / 199 |
| Equipment / loop type | HP - Split System | 199 / 199 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 199 / 199 |
| Compressor staging | Single stage | 199 / 199 |
| Connected capability | No | 199 / 199 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
PF5MN*B36L*AHRI reference: 214179766 | 15.50 | 7.80 | 11400 | 2.10 | EPA 3404555 → |
FT5ANXB24L*AHRI reference: 214179846 | 15.50 | 7.80 | 11200 | 2.08 | EPA 3404616 → |
FG5ANXB24L*AHRI reference: 214179847 | 15.50 | 7.80 | 11200 | 2.08 | EPA 3404617 → |
PF5TNXB24L*AHRI reference: 214179848 | 15.50 | 7.80 | 11200 | 2.08 | EPA 3404620 → |
CAA**2517AM*+ furnace: 916SA48060M17***AHRI reference: 214198020 | 15.50 | 7.80 | 11400 | 2.10 | EPA 3405035 → |
CAA**2517AM*+ furnace: 88*TB48090C17***AHRI reference: 214197595 | 15.50 | 7.80 | 11400 | 2.10 | EPA 3405463 → |
CAA**2517AM*+ furnace: 986TD42080C17***AHRI reference: 214198369 | 15.50 | 7.80 | 11300 | 2.10 | EPA 3405537 → |
CAA**2517AM*+ furnace: 986TD42060C17***AHRI reference: 214198342 | 15.50 | 7.80 | 11400 | 2.10 | EPA 3405548 → |
CAA**2517AM*+ furnace: 88*TB36045C17***AHRI reference: 214197541 | 15.50 | 7.80 | 11500 | 2.10 | EPA 3405593 → |
CAA**2517AM*+ furnace: 88*TB48070C17***AHRI reference: 214197568 | 15.50 | 7.80 | 11400 | 2.10 | EPA 3405642 → |
CAA**2517AM*+ furnace: 987MC42060C17***AHRI reference: 214197810 | 15.50 | 7.80 | 11500 | 2.10 | EPA 3405812 → |
CAA**2517AM*+ furnace: 935CB48060C17***AHRI reference: 214197729 | 15.50 | 7.80 | 11300 | 2.10 | EPA 3405820 → |
CAA**2517AM*+ furnace: 987MC42080C17***AHRI reference: 214197837 | 15.50 | 7.80 | 11500 | 2.12 | EPA 3405975 → |
CAA**3721AM*+ furnace: OVLAAB048112AHRI reference: 214203244 | 15.50 | 7.80 | 11500 | 2.10 | EPA 3406266 → |
CAA**3717AM*+ furnace: 8(0,1)*SB48070M17***AHRI reference: 214199788 | 15.50 | 7.80 | 11300 | 2.08 | EPA 3406283 → |
CVAMA3217XMA*+ furnace: 926SB48080V17***AHRI reference: 214204700 | 15.50 | 7.80 | 11300 | 1.98 | EPA 3406294 → |
CVAVA3117XMA*+ furnace: 935SB48060M17***AHRI reference: 214205597 | 15.50 | 7.80 | 11300 | 1.98 | EPA 3406407 → |
CAA**3721AM*+ furnace: 88*TB60110C21***AHRI reference: 214201951 | 15.50 | 7.80 | 11600 | 2.14 | EPA 3406420 → |
CAA**3721AM*+ furnace: 935SB60080M21***AHRI reference: 214202834 | 15.50 | 7.80 | 11600 | 2.14 | EPA 3406515 → |
CVAVA3817XMA*+ furnace: 926TC48080V17***AHRI reference: 214207775 | 15.50 | 7.80 | 11300 | 1.98 | EPA 3406593 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →