BRYANT HEATING AND COOLING SYSTEMS / AIR-SOURCE HEAT PUMP

235SAN024**AA*

LEGACY 15 SEER2 HP

199 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity22,200–24,400BTU/h

Each efficiency range summarizes published EPA records for 235SAN024**AA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 199 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.5199 / 199
EER2 · BTU/Wh11.7–13199 / 199
HSPF2 · BTU/Wh7.8–8.5199 / 199
Cooling capacity · BTU/h22,200–24,400199 / 199
Heating capacity at 47°F / 8.3°C · BTU/h21,600–24,000199 / 199
Heating capacity at 17°F / −8.3°C · BTU/h14,200–15,200199 / 199
Heating capacity at 5°F / −15°C · BTU/h10,800–11,900199 / 199
COP at 5°F / −15°C1.96–2.26199 / 199
Equipment / loop typeHP - Split System199 / 199
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)199 / 199
Compressor stagingSingle stage199 / 199
Connected capabilityNo199 / 199

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
FMA5X30**AL*AHRI reference: 21442407016.508.50116002.26EPA 3425353
CVAVA3117XMA*+ furnace: 82*SB48090V17***AHRI reference: 21420505816.007.80113001.98EPA 3408530
CVAVA3117XMA*+ furnace: 82*TB48090V17***AHRI reference: 21420520416.007.80113001.98EPA 3408931
CVAMA3217XMA*+ furnace: 83*SB48060M17***AHRI reference: 21421273416.007.80113002.00EPA 3408984
CVAVA3817XMA*+ furnace: 82*TB48090V17***AHRI reference: 21421438216.007.80114002.00EPA 3409037
CVAVA3817XMA*+ furnace: 82*TB48070V17***AHRI reference: 21421435416.007.80114002.00EPA 3409061
CVAVA3721XMA*+ furnace: 8(0,1)*SB48090M21***AHRI reference: 21421339116.007.80112001.98EPA 3409065
CAA**3721AM*+ furnace: 83*CA60080C21***AHRI reference: 21421090816.007.80113002.14EPA 3409113
CVAMA3217XMA*+ furnace: 82*SB48090V17***AHRI reference: 21421264516.007.80114001.98EPA 3409251
CAA**3721AM*+ furnace: 935SB60100M21***AHRI reference: 21421196616.007.80115002.14EPA 3409572
CVAVA3817XMA*+ furnace: 912SE42060M17***AHRI reference: 21421448116.007.80114002.00EPA 3409640
CAA**3721AM*+ furnace: 986TC66100C21***AHRI reference: 21421202116.007.80112002.12EPA 3409871
CVAMA3217XMA*+ furnace: 82*TB48090V17***AHRI reference: 21421289016.007.80114001.98EPA 3409892
CAA**3721AM*+ furnace: 986TD60080C21***AHRI reference: 21421204816.007.80114001.96EPA 3410106
CAA**3721AM*+ furnace: 986TD66100C21***AHRI reference: 21421207516.007.80115002.14EPA 3410132
CVAMA3217XMA*+ furnace: 912SE48080M17***AHRI reference: 21421299416.007.80112001.98EPA 3410183
CAA**2517AM*+ furnace: 83*SB36040M17***AHRI reference: 21421052616.007.80113002.12EPA 3410285
CAA**2517AM*+ furnace: 83*SB48060M17***AHRI reference: 21421055816.007.80112002.12EPA 3410529
CVAVA3817XMA*+ furnace: 8(0,1)*SB36070M17***AHRI reference: 21421397116.007.80114002.00EPA 3410632
CAA**3721AM*+ furnace: 88*TB60090C21***AHRI reference: 21421142816.007.80115002.14EPA 3410674

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.