BROCK / AIR-SOURCE HEAT PUMP

PH5SAN524**AA*

15 SEER2 HP · source records, page 4

116 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity22,200–24,400BTU/h

Each efficiency range summarizes published EPA records for PH5SAN524**AA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 116 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.5116 / 116
EER2 · BTU/Wh11.7–13116 / 116
HSPF2 · BTU/Wh7.8–8.5116 / 116
Cooling capacity · BTU/h22,200–24,400116 / 116
Heating capacity at 47°F / 8.3°C · BTU/h21,600–24,000116 / 116
Heating capacity at 17°F / −8.3°C · BTU/h14,200–15,200116 / 116
Heating capacity at 5°F / −15°C · BTU/h10,800–11,900116 / 116
COP at 5°F / −15°C1.98–2.26116 / 116
Equipment / loop typeHP - Split System116 / 116
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)116 / 116
Compressor stagingSingle stage116 / 116
Connected capabilityNo116 / 116

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CAA**3721AM*+ furnace: PG80MSUA36040B**AHRI reference: 21421129015.507.80115002.16EPA 3410326
CAA**3721AM*+ furnace: PG80MSUA60080C**AHRI reference: 21421135015.507.80114002.16EPA 3410581
CVAMA3217XMA*+ furnace: PG80MS(A,L)A48070B**AHRI reference: 21421251215.507.80114002.00EPA 3411186
CVAMA3217XMA*+ furnace: PG80MS(A,L)A36070B**AHRI reference: 21421248215.507.80114002.00EPA 3411273
CAA**3717AM*+ furnace: PG80MSUA48060B**AHRI reference: 21421082815.507.80112002.10EPA 3411398
FEVB0036**+NAVA53601CKAHRI reference: 21427755715.507.80114002.08EPA 3415802
FMA5X24**AL*AHRI reference: 21442404315.507.80108002.00EPA 3425326
FM(C,U)5Z24**AL*AHRI reference: 21582890315.508.00113002.10EPA 3713317
FEVA0036**+NAVA53601CKAHRI reference: 21705151915.508.00113002.04EPA 4027336
FM(C,U)5S36**AL*AHRI reference: 21845231215.508.00112002.10EPA 4624433
FM(C,U)5S30**AL*AHRI reference: 21845228015.508.00112002.10EPA 4624465
CAA**2517AM*+ furnace: PG96MSAA30026A**AHRI reference: 21413085315.207.80116002.08EPA 3399918
CAA**2517AM*+ furnace: PG96MSAA36060A**AHRI reference: 21413088115.207.80116002.08EPA 3399976
CAA**3717AM*+ furnace: PG96MSAA30026A**AHRI reference: 21413290415.207.80115002.06EPA 3400029
CAA**3717AM*+ furnace: PG96MSAA36060A**AHRI reference: 21413293215.207.80116002.06EPA 3400057
CAA**3717AM*+ furnace: PG96VTAB36060A**AHRI reference: 21413310915.207.80115002.06EPA 3400096
CAA**3721AM*+ furnace: PG95MSUA36040B**AHRI reference: 21413322415.207.80118002.10EPA 3400160
CAA**3717AM*+ furnace: PG80MS(A,L)A42045B**AHRI reference: 21413263015.207.80114002.08EPA 3400234
CAA**2517AM*+ furnace: PG96VTAB36060A**AHRI reference: 21413102615.207.80115002.08EPA 3400286
PF5MN*B30L*AHRI reference: 21417973915.207.80111002.06EPA 3404528

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →