Breeze33 / AIR-SOURCE HEAT PUMP

4HP17L30P-**A

4HP17 SERIES · 4HP17L · 4HP17L SERIES · 4HP17L Series · source records, page 7

198 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.2BTU/Wh
HSPF2 range7.8–8.6BTU/Wh
Cooling capacity28,200–30,600BTU/h

Each efficiency range summarizes published EPA records for 4HP17L30P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 198 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.2198 / 198
EER2 · BTU/Wh12.2–13.5198 / 198
HSPF2 · BTU/Wh7.8–8.6198 / 198
Cooling capacity · BTU/h28,200–30,600198 / 198
Heating capacity at 47°F / 8.3°C · BTU/h26,600–30,000198 / 198
Heating capacity at 17°F / −8.3°C · BTU/h17,400–19,600198 / 198
Heating capacity at 5°F / −15°C · BTU/h13,200–15,400198 / 198
COP at 5°F / −15°C1.96–2.36198 / 198
Equipment / loop typeHP - Split System198 / 198
Refrigerant / source-reported GWPR-410A (GWP:2088)198 / 198
Compressor stagingSingle stage198 / 198
Connected capabilityNo198 / 198

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EAH1P36C*+TDR+TXV+ furnace: 92G1UH090CE12AHRI reference: 21331554915.608.30147002.24EPA 2840993
EAH1P36C*+TDR+TXV+ furnace: 92G1UH090CE16AHRI reference: 21331555015.608.30146002.24EPA 2840994
EAH1P36C*+TDR+TXV+ furnace: 92G1UH110CE20AHRI reference: 21331555215.608.50148002.24EPA 2840995
EAH1P36C*+TDR+TXV+ furnace: 96G1UH110CE20AHRI reference: 21331555415.608.50148002.26EPA 2841001
EAD4X-42B+TDR+ furnace: 96G1DF070BE16AHRI reference: 21331553615.608.60153002.32EPA 2841163
EAH1P36C*+TDR+TXV+ furnace: 96G1UH090CE16AHRI reference: 21331555315.608.30145002.22EPA 2841173
EA(C;U)1P30B+TDR+TXV+ furnace: 92G1UH070BE12AHRI reference: 21331546515.608.00144002.20EPA 2841176
7EH30BX-0*+TDR+ furnace: 96G1UH030BE08AHRI reference: 21470869115.607.80138002.10EPA 3491599
7EH36CX-0*+TDR+ furnace: 80G2UH110CE20AHRI reference: 21470869915.608.50148002.22EPA 3491728
7EC36BX-0*+TDR+ furnace: 97G2UH045BV12AHRI reference: 21470877715.608.10145002.26EPA 3491730
7ED42BX-0*+TDR+ furnace: 97G2DF045BE12AHRI reference: 21470871815.608.50151002.32EPA 3491736
7EC30BX-0*+TDR+ furnace: 92G1UH045BE12AHRI reference: 21470875215.608.00144002.20EPA 3491782
7EH36CX-0*+TDR+ furnace: 97G2UH090CV12AHRI reference: 21470870215.608.30147002.22EPA 3491786
7EC30AX-0*+TDR+ furnace: 80G1UH060AE12XAHRI reference: 21470872815.607.80142002.20EPA 3491815
7EC30AX-0*+TDR+ furnace: 80G2UH070AE12LAHRI reference: 21470873115.608.00144002.20EPA 3491816
7ED42BX-0*+TDR+ furnace: 97G2DF070BE16AHRI reference: 21470871915.608.50151002.32EPA 3494318
7EH30AX-0*+TDR+ furnace: 80G2UH070AV12AHRI reference: 21470867215.607.80139001.98EPA 3494330
7EH30BX-0*+TDR+ furnace: 96G1UH045BE12AHRI reference: 21470869215.607.80138002.06EPA 3494343
7EH30BX-0*+TDR+ furnace: 96G1UH070BE12AHRI reference: 21470869315.607.80138002.06EPA 3494344
7EC30AX-0*+TDR+ furnace: 80G1UH070AE12AHRI reference: 21470873415.608.00144002.20EPA 3494360

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →