Breeze33 / AIR-SOURCE HEAT PUMP

4HP17L30P-**A

4HP17 SERIES · 4HP17L · 4HP17L SERIES · 4HP17L Series · source records, page 5

198 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.2BTU/Wh
HSPF2 range7.8–8.6BTU/Wh
Cooling capacity28,200–30,600BTU/h

Each efficiency range summarizes published EPA records for 4HP17L30P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 198 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.2198 / 198
EER2 · BTU/Wh12.2–13.5198 / 198
HSPF2 · BTU/Wh7.8–8.6198 / 198
Cooling capacity · BTU/h28,200–30,600198 / 198
Heating capacity at 47°F / 8.3°C · BTU/h26,600–30,000198 / 198
Heating capacity at 17°F / −8.3°C · BTU/h17,400–19,600198 / 198
Heating capacity at 5°F / −15°C · BTU/h13,200–15,400198 / 198
COP at 5°F / −15°C1.96–2.36198 / 198
Equipment / loop typeHP - Split System198 / 198
Refrigerant / source-reported GWPR-410A (GWP:2088)198 / 198
Compressor stagingSingle stage198 / 198
Connected capabilityNo198 / 198

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
7EC30AX-0*+TDR+ furnace: 80G1UH045AE12AHRI reference: 21470873215.808.00141002.20EPA 3494471 →
7EC30AX-0*+TDR+ furnace: 80G1UH045AE12LAHRI reference: 21470873315.808.00141002.20EPA 3494472 →
7EH36CX-0*+TDR+ furnace: 97G2UH090CE16AHRI reference: 21470870115.808.30145002.20EPA 3494478 →
7EC36BX-0*+TDR+ furnace: 97G2UH045BE12AHRI reference: 21470877615.808.10143002.24EPA 3494481 →
7EC36BX-0*+TDR+ furnace: 97G2UH070BE12AHRI reference: 21470877815.808.00143002.20EPA 3494482 →
7EH36CX-0*+TDR+ furnace: 80G1UH090CE20AHRI reference: 21470870615.808.50148002.26EPA 3494498 →
7EC36BX-0*+TDR+ furnace: 92G1UH030BE12AHRI reference: 21470878415.808.10142002.26EPA 3494537 →
7EC36BX-0*+TDR+ furnace: 92G1UH045BE12AHRI reference: 21470878515.808.10143002.26EPA 3494538 →
7EH30BX-0*+TDR+ furnace: 97G2UH070BV12AHRI reference: 21470868315.808.00137002.08EPA 3494589 →
7ED42BX-0*+TDR+ furnace: 80G2DF090BE16AHRI reference: 21470871715.808.60151002.32EPA 3543586 →
7EH36CX-0*+TDR+ furnace: 92G1UH110CE16AHRI reference: 21470871115.808.30147002.24EPA 3543593 →
7EC30BX-0*+TDR+ furnace: 80G1UH070BE12LAHRI reference: 21470874815.808.00144002.22EPA 3543705 →
7EC30BX-0*+TDR+ furnace: 80G1UH070BE12AHRI reference: 21470874715.808.00144002.22EPA 3543706 →
7EH30AX-0*+TDR+ furnace: 80G2UH045AE12AHRI reference: 21470866515.807.80138002.00EPA 3543714 →
7EC36AX-0*+TDR+ furnace: 80G2UH070AV12AHRI reference: 21470876815.808.10144002.26EPA 3543731 →
7AH1AV36PX-0*AHRI reference: 21486538615.808.10134002.16EPA 3553768 →
7AH1AE30PX-0*AHRI reference: 21486542015.807.80137002.14EPA 3553788 →
7AH2AE30PX-0*AHRI reference: 21486535615.808.50147002.36EPA 3553845 →
EAC4X36B+TDR+ furnace: 96G1UH030BE08AHRI reference: 21331552315.608.00143002.24EPA 2840660 →
EAC4X36B+TDR+ furnace: 96G1UH045BE12AHRI reference: 21331552415.608.10146002.26EPA 2840661 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →