Bosch / AIR-SOURCE HEAT PUMP

BOVB-60RTB-M20S

IDS Premium LGWP · source records, page 2

25 published source records · source checked Sep 21, 2026

SEER2 range16–18.5BTU/Wh
HSPF2 range8.5–9.5BTU/Wh
Cooling capacity42,500–52,000BTU/h

Each efficiency range summarizes published EPA records for BOVB-60RTB-M20S. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 25 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh16–18.525 / 25
EER2 · BTU/Wh11.4–1225 / 25
HSPF2 · BTU/Wh8.5–9.525 / 25
Cooling capacity · BTU/h42,500–52,00025 / 25
Heating capacity at 47°F / 8.3°C · BTU/h43,500–55,00025 / 25
Heating capacity at 17°F / −8.3°C · BTU/h35,000–44,00025 / 25
Heating capacity at 5°F / −15°C · BTU/h31,000–38,50025 / 25
COP at 5°F / −15°C1.8–225 / 25
Equipment / loop typeHP - Split System25 / 25
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)25 / 25
Compressor stagingContinuously variable25 / 25
Connected capabilityYes25 / 25

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
BMAC4248CBTA+ furnace: BGH96M080C4CCold climate designationAHRI reference: 21789528116.008.80314001.80EPA 4512116
BMAC4248BBTA+ furnace: BGH97M080B3ACold climate designationAHRI reference: 21789534616.008.80310001.80EPA 4512171
BMAC4248CBTA+ furnace: BGH97M080C4ACold climate designationAHRI reference: 21789534716.008.80314001.80EPA 4512172
BMAC4248BBTA+BMXFBCTACold climate designationAHRI reference: 21789540216.008.80310001.80EPA 4512219
BMAC4248BBTA+ furnace: BGH96M080B3CCold climate designationAHRI reference: 21789528016.008.80310001.80EPA 4512241

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →