BOVB-36MTB-M19E
IDS Ultra · source records, page 2
31 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for BOVB-36MTB-M19E. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 31 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–19 | 31 / 31 |
| EER2 · BTU/Wh | 10.6–12 | 31 / 31 |
| HSPF2 · BTU/Wh | 9–10 | 31 / 31 |
| Cooling capacity · BTU/h | 32,200–36,400 | 31 / 31 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 34,800–36,600 | 31 / 31 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 34,600–36,600 | 31 / 31 |
| Heating capacity at 5°F / −15°C · BTU/h | 32,200–36,600 | 31 / 31 |
| COP at 5°F / −15°C | 1.8–2.1 | 31 / 31 |
| Equipment / loop type | HP - Split System | 31 / 31 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 31 / 31 |
| Compressor staging | Continuously variable | 31 / 31 |
| Connected capability | Yes | 31 / 31 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
BMAC3036ABTA+ furnace: BGH97M060B3ACold climate designationAHRI reference: 217992571 | 17.00 | 9.00 | 32800 | 2.00 | EPA 4515719 → |
BMAC3036ABTA+ furnace: BGH97M080B3ACold climate designationAHRI reference: 217992572 | 17.00 | 9.00 | 32800 | 2.00 | EPA 4515720 → |
BMAC4248BBTACold climate designationAHRI reference: 217903125 | 16.00 | 9.00 | 32800 | 1.90 | EPA 4515631 → |
BMAC4248CBTACold climate designationAHRI reference: 217903126 | 16.00 | 9.00 | 32800 | 1.90 | EPA 4515632 → |
BMAC4248DBTACold climate designationAHRI reference: 217903127 | 16.00 | 9.00 | 32800 | 1.90 | EPA 4515633 → |
BMAC3036CBTA+ furnace: BGH96M100C5CCold climate designationAHRI reference: 217903133 | 16.00 | 9.50 | 33200 | 2.00 | EPA 4515638 → |
BMAC3036CBTA+ furnace: BGH97M100C5CCold climate designationAHRI reference: 217903141 | 16.00 | 9.50 | 33200 | 2.00 | EPA 4515646 → |
BMAC3036CBTA+ furnace: BGH97M100C5ACold climate designationAHRI reference: 217992576 | 16.00 | 9.50 | 33200 | 2.00 | EPA 4515722 → |
BMAC3036BBTACold climate designationAHRI reference: 217903123 | 15.20 | 9.00 | 32400 | 1.85 | EPA 4515629 → |
BMAC3036CBTACold climate designationAHRI reference: 217903124 | 15.20 | 9.00 | 32400 | 1.85 | EPA 4515630 → |
BMAC3036ABTACold climate designationAHRI reference: 217903122 | 15.20 | 9.00 | 32200 | 1.80 | EPA 4523790 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →