Bosch / AIR-SOURCE HEAT PUMP

BOVA-60RXB-M15S

IDS Light-LGWP

19 published source records · source checked Sep 21, 2026

SEER2 range16–17BTU/Wh
HSPF2 range8.5BTU/Wh
Cooling capacity34,200–55,000BTU/h

Each efficiency range summarizes published EPA records for BOVA-60RXB-M15S. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 19 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh16–1719 / 19
EER2 · BTU/Wh10–11.719 / 19
HSPF2 · BTU/Wh8.519 / 19
Cooling capacity · BTU/h34,200–55,00019 / 19
Heating capacity at 47°F / 8.3°C · BTU/h34,200–56,00019 / 19
Heating capacity at 17°F / −8.3°C · BTU/h33,000–40,00019 / 19
Heating capacity at 5°F / −15°C · BTU/h31,000–39,50019 / 19
COP at 5°F / −15°C1.8–1.8719 / 19
Equipment / loop typeHP - Split System19 / 19
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)19 / 19
Compressor stagingContinuously variable19 / 19
Connected capabilityNo19 / 19

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
BIVA-48RCB-M20XCold climate designationAHRI reference: 21522510817.008.50336001.87EPA 3557152 →
BIVA-36RCB-M20XCold climate designationAHRI reference: 21522510917.008.50342001.80EPA 3557153 →
BIVB-48RCB-M20XCold climate designationAHRI reference: 21789520817.008.50336001.87EPA 4512056 →
BIVB-36RCB-M20XCold climate designationAHRI reference: 21789520917.008.50342001.80EPA 4512057 →
BIVA-60RCB-M20XCold climate designationAHRI reference: 21522511016.508.50395001.87EPA 3557154 →
BIVB-60RCB-M20XCold climate designationAHRI reference: 21789521016.508.50395001.87EPA 4512058 →
BMAC4248BBTA+ furnace: BGH96M080B3CCold climate designationAHRI reference: 21522511116.008.50310001.85EPA 3557155 →
BMAC4248CBTA+ furnace: BGH96M080C4CCold climate designationAHRI reference: 21522511216.008.50316001.85EPA 3557156 →
BMAC4248CBTA+ furnace: BGH96M100C5CCold climate designationAHRI reference: 21522511316.008.50330001.85EPA 3557157 →
BMAC4248DBTA+ furnace: BGH96M100D5CCold climate designationAHRI reference: 21522511416.008.50330001.85EPA 3557158 →
BMAC4248DBTA+ furnace: BGH96M120D5CCold climate designationAHRI reference: 21522511516.008.50330001.85EPA 3557159 →
BMAC4248BBTA+ furnace: BGH97M080B3ACold climate designationAHRI reference: 21789521616.008.50310001.85EPA 4512064 →
BMAC4248CBTA+ furnace: BGH97M080C4ACold climate designationAHRI reference: 21789521716.008.50316001.85EPA 4512065 →
BMAC4248DBTA+ furnace: BGH97M100D5ACold climate designationAHRI reference: 21789521916.008.50330001.85EPA 4512066 →
BMAC4248BBTA+BMXFBCTACold climate designationAHRI reference: 21789539216.008.50310001.85EPA 4512209 →
BMAC4248CBTA+BMXFCCTACold climate designationAHRI reference: 21789539316.008.50330001.85EPA 4512210 →
BMAC4248DBTA+BMXFDCTACold climate designationAHRI reference: 21789539416.008.50330001.85EPA 4512211 →
BMAC4248CBTA+ furnace: BGH97M100C5ACold climate designationAHRI reference: 21789521816.008.50330001.85EPA 4512228 →
BMAC4248DBTA+ furnace: BGH97M120D5ACold climate designationAHRI reference: 21789522016.008.50330001.85EPA 4512229 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →