Bosch / AIR-SOURCE HEAT PUMP

BOVA-36RTB-M20S

IDS Premium LGWP

40 published source records · source checked Sep 21, 2026

SEER2 range15.2–20BTU/Wh
HSPF2 range9–9.5BTU/Wh
Cooling capacity23,000–34,200BTU/h

Each efficiency range summarizes published EPA records for BOVA-36RTB-M20S. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 40 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–2040 / 40
EER2 · BTU/Wh10.6–1340 / 40
HSPF2 · BTU/Wh9–9.540 / 40
Cooling capacity · BTU/h23,000–34,20040 / 40
Heating capacity at 47°F / 8.3°C · BTU/h24,000–34,20040 / 40
Heating capacity at 17°F / −8.3°C · BTU/h19,400–28,00040 / 40
Heating capacity at 5°F / −15°C · BTU/h16,800–24,40040 / 40
COP at 5°F / −15°C1.85–240 / 40
Equipment / loop typeHP - Split System40 / 40
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)40 / 40
Compressor stagingContinuously variable40 / 40
Connected capabilityNo40 / 40

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
BIVA-24RCB-M20XCold climate designationAHRI reference: 21477171020.009.50174002.00EPA 3542844
BIVB-24RCB-M20XCold climate designationAHRI reference: 21789524320.009.50174002.00EPA 4512232
BIVA-36RCB-M20XCold climate designationAHRI reference: 21477171119.009.50244002.00EPA 3542845
BIVB-36RCB-M20XCold climate designationAHRI reference: 21789524519.009.50244002.00EPA 4512231
BMAC2430BBTA+ furnace: BGH96M060B3CCold climate designationAHRI reference: 21477171418.509.00172001.90EPA 3542848
BMAC2430BBTA+ furnace: BGH96M080B3CCold climate designationAHRI reference: 21477171518.509.00172001.90EPA 3542849
BMAC2430BBTA+ furnace: BGH97M060B3ACold climate designationAHRI reference: 21789522518.509.00172001.90EPA 4512071
BMAC2430BBTA+ furnace: BGH97M080B3ACold climate designationAHRI reference: 21789522618.509.00172001.90EPA 4512072
BMAC2430BBTA+BMXFBCTACold climate designationAHRI reference: 21789537818.509.00172001.90EPA 4512198
BMAC2430ABTA+ furnace: BGH96M060B3CCold climate designationAHRI reference: 21477171218.009.00168001.85EPA 3542846
BMAC2430ABTA+ furnace: BGH96M080B3CCold climate designationAHRI reference: 21477171318.009.00168001.85EPA 3542847
BMAC4248BBTA+ furnace: BGH96M080B3CCold climate designationAHRI reference: 21477172218.009.00240001.88EPA 3542856
BMAC4248CBTA+ furnace: BGH96M100C5CCold climate designationAHRI reference: 21477172318.009.00242001.90EPA 3542857
BMAC2430ABTA+ furnace: BGH97M060B3ACold climate designationAHRI reference: 21789522318.009.00168001.85EPA 4512069
BMAC2430ABTA+ furnace: BGH97M080B3ACold climate designationAHRI reference: 21789522418.009.00168001.85EPA 4512070
BMAC4248BBTA+ furnace: BGH97M080B3ACold climate designationAHRI reference: 21789523318.009.00240001.88EPA 4512078
BMAC4248CBTA+ furnace: BGH97M100C5ACold climate designationAHRI reference: 21789523418.009.00242001.90EPA 4512079
BMAC2430ABTA+BMXFACTACold climate designationAHRI reference: 21789537718.009.00168001.85EPA 4512255
BMAC3036BBTA+ furnace: BGH96M060B3CCold climate designationAHRI reference: 21477171817.509.00240001.88EPA 3542852
BMAC3036BBTA+ furnace: BGH96M080B3CCold climate designationAHRI reference: 21477171917.509.00240001.90EPA 3542853

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →