SEER2 range19.5–26BTU/Wh
HSPF2 range11–13.9BTU/Wh
Cooling capacity9,000BTU/h

Each efficiency range summarizes published EPA records for BXS3A09SC0. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 6 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh19.5–266 / 6
EER2 · BTU/Wh12.8–16.26 / 6
HSPF2 · BTU/Wh11–13.96 / 6
Cooling capacity · BTU/h9,0006 / 6
Heating capacity at 47°F / 8.3°C · BTU/h9,000–11,0006 / 6
Heating capacity at 17°F / −8.3°C · BTU/h7,900–9,3006 / 6
Heating capacity at 5°F / −15°C · BTU/h8,000–8,6006 / 6
COP at 5°F / −15°C2.17–2.366 / 6
Equipment / loop typeHP - Mini or Multi Split6 / 6
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)6 / 6
Compressor stagingContinuously variable6 / 6
Connected capabilityNo6 / 6

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
BXAFA09LW0Cold climate designationAHRI reference: 21699755026.0013.9086002.27EPA 3997878
BXAFA09WM0Cold climate designationAHRI reference: 21699752225.8012.5080002.36EPA 3997850
BXAFA09CC1Cold climate designationAHRI reference: 21699754022.1011.8080002.18EPA 3997868
BXAFA09CC4Cold climate designationAHRI reference: 21699753621.6011.3083002.17EPA 3997864
BXAFA09CDHCold climate designationAHRI reference: 21699754619.7011.5083002.31EPA 3997874
BXAFA09CDLCold climate designationAHRI reference: 21699754319.5011.0086002.25EPA 3997871