BLUERIDGE / AIR-SOURCE HEAT PUMP

BHP17L48P-**A

BHP17 Series · BHP17L SERIES · BHP17L Series

85 published source records · source checked Sep 21, 2026

SEER2 range15.2–15.6BTU/Wh
HSPF2 range8–8.3BTU/Wh
Cooling capacity46,000–48,000BTU/h

Each efficiency range summarizes published EPA records for BHP17L48P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 85 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–15.685 / 85
EER2 · BTU/Wh12.5–1385 / 85
HSPF2 · BTU/Wh8–8.385 / 85
Cooling capacity · BTU/h46,000–48,00085 / 85
Heating capacity at 47°F / 8.3°C · BTU/h44,500–47,00085 / 85
Heating capacity at 17°F / −8.3°C · BTU/h30,000–31,60085 / 85
Heating capacity at 5°F / −15°C · BTU/h24,200–25,60085 / 85
COP at 5°F / −15°C2.18–2.3885 / 85
Equipment / loop typeHP - Split System85 / 85
Refrigerant / source-reported GWPR-410A (GWP:2088)85 / 85
Compressor stagingSingle stage85 / 85
Connected capabilityNo85 / 85

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
BC4X60C+TDR+ furnace: BG801UH090CE20AHRI reference: 21044140615.608.10252002.38EPA 2456736
BC4X49C+TDR+ furnace: BG801UH090CE20AHRI reference: 21044139515.608.10250002.26EPA 2458623
BC1P49C+TDR+TXV+ furnace: BG801UH090CE20AHRI reference: 21032514215.608.10250002.26EPA 2460333
BC1P60C+TDR+TXV+ furnace: BG801UH090CE20AHRI reference: 21032516515.608.10252002.38EPA 2461146
BH1P51C*+TDR+TXV+ furnace: BG801UH090CE20AHRI reference: 21173725115.608.30252002.30EPA 2462833
BC760CCT-0*+TDR+ furnace: BG801UH090CE20AHRI reference: 21471362815.608.10252002.38EPA 3487277
BC751HCT-0*+TDR+ furnace: BG801UH090CE20AHRI reference: 21471359115.608.30252002.30EPA 3487416
BC749CCT-0*+TDR+ furnace: BG801UH090CE20AHRI reference: 21471361215.608.10250002.26EPA 3487501
BC1P60C+TDR+TXV+ furnace: BG921UH110CE20AHRI reference: 21032517015.408.30254002.32EPA 2455331
BC1P49C+TDR+TXV+ furnace: BG921UH110CE20AHRI reference: 21032514415.408.10250002.24EPA 2455570
BC1P48B+TDR+TXV+ furnace: BG801UH090CE20AHRI reference: 21032512015.408.10244002.22EPA 2455707
BC1P48C+TDR+TXV+ furnace: BG801UH090CE20AHRI reference: 21044136415.408.10244002.22EPA 2456440
BC4X48C+TDR+ furnace: BG921UH110CE20AHRI reference: 21044138815.408.10244002.18EPA 2456477
BC4X48C+TDR+ furnace: BG801UH090CE20AHRI reference: 21044138415.408.10244002.22EPA 2456490
BC4X49C+TDR+ furnace: BG921UH110CE20AHRI reference: 21044139915.408.10250002.24EPA 2456513
BC4X60C+TDR+ furnace: BG961UH110CE20AHRI reference: 21044141215.408.10252002.34EPA 2456529
BC4X60C+TDR+ furnace: BG921UH110CE16AHRI reference: 21044140915.408.10252002.36EPA 2457296
BC4X60C+TDR+ furnace: BG801UH110CE20AHRI reference: 21044140715.408.30254002.34EPA 2457302
BC4X60C+TDR+ furnace: BG921UH110CE20AHRI reference: 21044141015.408.30254002.32EPA 2457309
BC4X60C+TDR+ furnace: BG961UH090CE16AHRI reference: 21044141115.408.10254002.36EPA 2458001

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.