BLUERIDGE / AIR-SOURCE HEAT PUMP

BHP17L42P-**A

BHP17 SERIES · BHP17 Series · BHP17L SERIES · BHP17L Series

37 published source records · source checked Sep 21, 2026

SEER2 range15.2–15.6BTU/Wh
HSPF2 range7.8–8.3BTU/Wh
Cooling capacity40,000–41,500BTU/h

Each efficiency range summarizes published EPA records for BHP17L42P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 37 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–15.637 / 37
EER2 · BTU/Wh12.5–1337 / 37
HSPF2 · BTU/Wh7.8–8.337 / 37
Cooling capacity · BTU/h40,000–41,50037 / 37
Heating capacity at 47°F / 8.3°C · BTU/h37,600–42,00037 / 37
Heating capacity at 17°F / −8.3°C · BTU/h25,000–27,60037 / 37
Heating capacity at 5°F / −15°C · BTU/h19,600–22,00037 / 37
COP at 5°F / −15°C2.02–2.1437 / 37
Equipment / loop typeHP - Split System37 / 37
Refrigerant / source-reported GWPR-410A (GWP:2088)37 / 37
Compressor stagingSingle stage37 / 37
Connected capabilityNo37 / 37

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
BC742HBT-0*+TDR+ furnace: BG802UH090BE16AHRI reference: 21471352215.607.80199002.12EPA 3487309 →
BC748DCT-0*+TDR+ furnace: BG80G1DF110CE20AHRI reference: 21471355215.608.30218002.12EPA 3487376 →
BC1P49C+TDR+TXV+ furnace: BG801UH090CE20AHRI reference: 21032524315.407.80198002.12EPA 2455763 →
BC4X49C+TDR+ furnace: BG801UH110CE20AHRI reference: 21044135315.407.80198002.10EPA 2457529 →
BC4X49C+TDR+ furnace: BG921UH110CE16AHRI reference: 21044135615.407.80198002.10EPA 2457974 →
BC4X49C+TDR+ furnace: BG801UH090CE20AHRI reference: 21044135215.407.80198002.12EPA 2458281 →
BC1P49C+TDR+TXV+ furnace: BG801UH110CE20AHRI reference: 21032524515.407.80198002.10EPA 2458599 →
BC1P49C+TDR+TXV+ furnace: BG921UH110CE16AHRI reference: 21032525315.407.80198002.10EPA 2461887 →
BE5V42MA4XAHRI reference: 21032524115.408.10202002.14EPA 2462134 →
BC748CCT-0*+TDR+ furnace: BG801UH110CE20AHRI reference: 21471356415.407.80196002.10EPA 3487059 →
BC742HBT-0*+TDR+ furnace: BG802UH090BE12AHRI reference: 21471352115.407.80199002.10EPA 3487307 →
BC742HBT-0*+TDR+ furnace: BG801UH070BE12AHRI reference: 21471352315.407.80202002.12EPA 3487310 →
BC742HBT-0*+TDR+ furnace: BG801UH090BE16AHRI reference: 21471352415.407.80200002.12EPA 3487311 →
BC749CCT-0*+TDR+ furnace: BG801UH090CE20AHRI reference: 21471357215.407.80198002.12EPA 3487428 →
BC749CCT-0*+TDR+ furnace: BG801UH110CE20AHRI reference: 21471357315.407.80198002.10EPA 3487430 →
BC748CCT-0*+TDR+ furnace: BG921UH110CE16AHRI reference: 21471356715.407.80196002.10EPA 3487470 →
BC748CCT-0*+TDR+ furnace: BG921UH110CE20AHRI reference: 21471356815.407.80199002.10EPA 3487471 →
BC749CCT-0*+TDR+ furnace: BG921UH110CE16AHRI reference: 21471357615.407.80198002.10EPA 3487497 →
BAH7V42PT-0*AHRI reference: 21486613115.408.10202002.14EPA 3553920 →
BC1P49C+TDR+TXV+ furnace: BG961UH110CE20AHRI reference: 21032524915.207.80199002.08EPA 2455425 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →