BLUERIDGE / AIR-SOURCE HEAT PUMP

BHP17L36P-**A

BHP17 SERIES · BHP17 Series · BHP17L SERIES · BHP17L Series

131 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.8BTU/Wh
HSPF2 range7.8–8.7BTU/Wh
Cooling capacity35,000–36,000BTU/h

Each efficiency range summarizes published EPA records for BHP17L36P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 131 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.8131 / 131
EER2 · BTU/Wh12.2–13.5131 / 131
HSPF2 · BTU/Wh7.8–8.7131 / 131
Cooling capacity · BTU/h35,000–36,000131 / 131
Heating capacity at 47°F / 8.3°C · BTU/h32,400–36,000131 / 131
Heating capacity at 17°F / −8.3°C · BTU/h21,400–23,800131 / 131
Heating capacity at 5°F / −15°C · BTU/h16,800–19,100131 / 131
COP at 5°F / −15°C2.08–2.34131 / 131
Equipment / loop typeHP - Split System131 / 131
Refrigerant / source-reported GWPR-410A (GWP:2088)131 / 131
Compressor stagingSingle stage131 / 131
Connected capabilityNo131 / 131

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
BC748CCT-0*+TDR+ furnace: BG801UH090CE20AHRI reference: 21471350116.807.80168002.14EPA 3486647
BC4X36B+TDR+ furnace: BG801UH090BE16AHRI reference: 21044133516.607.80168002.14EPA 2456509
BC1P36B+TDR+TXV+ furnace: BG801UH090BE16AHRI reference: 21044130816.607.80168002.14EPA 2457096
BC1P36A+TDR+TXV+ furnace: BG801UH090BE16AHRI reference: 21032535816.607.80168002.14EPA 2461870
BH1P51C*+TDR+TXV+ furnace: BG801UH090CE20AHRI reference: 21173668616.608.00174002.22EPA 2467525
BC742HCT-0*+TDR+ furnace: BG921UH110CE16AHRI reference: 21471344916.608.00179002.20EPA 3487255
BC742HCT-0*+TDR+ furnace: BG961UH110CE20AHRI reference: 21471345216.608.00178002.20EPA 3487261
BC748CCT-0*+TDR+ furnace: BG801UH110CE20AHRI reference: 21471350216.608.00170002.14EPA 3487319
BC748CCT-0*+TDR+ furnace: BG921UH090CE16AHRI reference: 21471350416.607.80168002.12EPA 3487321
BC748CCT-0*+TDR+ furnace: BG921UH110CE16AHRI reference: 21471350516.607.80170002.14EPA 3487322
BC748CCT-0*+TDR+ furnace: BG921UH110CE20AHRI reference: 21471350616.607.80168002.14EPA 3487324
BC748CCT-0*+TDR+ furnace: BG961UH090CE16AHRI reference: 21471350716.607.80170002.16EPA 3487325
BC748CCT-0*+TDR+ furnace: BG961UH110CE20AHRI reference: 21471350816.607.80170002.18EPA 3487327
BC751HCT-0*+TDR+ furnace: BG801UH090CE20AHRI reference: 21471346416.608.00174002.22EPA 3487443
BC736CBT-0*+TDR+ furnace: BG801UH090BE16AHRI reference: 21471349316.607.80168002.14EPA 3487528
BC748DCT-0*+TDR+ furnace: BG80G1DF110CE20AHRI reference: 21471348116.608.70188002.34EPA 3491769
BC4X36B+TDR+ furnace: BG802UH090BE16AHRI reference: 21044133216.407.80170002.14EPA 2456467
BC1P36B+TDR+TXV+ furnace: BG802UH090BE16AHRI reference: 21044130516.407.80170002.14EPA 2456502
BC1P36A+TDR+TXV+ furnace: BG802UH090BE16AHRI reference: 21032530216.407.80170002.14EPA 2458320
BC4X36B+TDR+ furnace: BG802UH090BE12AHRI reference: 21044133116.407.80170002.14EPA 2458830

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →